3.2 Example of systems for ADAT (3 units) and BRC
This system is configured using 3 ADATs and a BRC connected using the ADAT Sync cables and the three ADAT units are being
Method of connection
With the mixer powered OFF insert the option card
Connect the
The BRC functions as the wordclock master. Connect the WORD OUT of the BRC to WORD CLOCK IN of the
For MIDI connection, connect the
For the timecode, MTC is received using the MIDI connection. (Using the option card
For MMC, set MMC PORT to ‘MIDI’ in the MIDI SETUP screen. The MIDI channels should be set to the same MIDI channel of the MMC being received on the BRC.
To receive MTC on the DA7, set the MTC PORT to ‘MIDI’ in the MIDI SETUP screen of the WR- DA7.
To have the MTC read out on the LCD screen, set the TIME BASE to ‘MTC’ in the EXECUTE screen of AUTOMATION SETUP.
(For SMPTE timecode using the optional
ADAT setting
For ADAT wordclock setting, connect a Sync cable from the BRC and turn on the power supply. At that time, the setting is automatically set to ‘EXT’ and the ADAT works as a slave to the BRC.
The ADAT ID numbers are automatically set from 1, in the sequential order of the SYNC cable con- nections from SYNC OUT to SYNC IN.
The power supply of each ADAT should be turned on in the sequential order, starting with the last unit located at the end of SYNC cable connections to the first unit. Finally, turn of the power sup- ply of the BRC.
The audio input of the ADAT needs to be selected into the digital input mode. Press, the DIGITAL IN buttons on the front panel of each ADAT being used.
17