For proper tandem connections, select the TANDEM setting to ‘ON’ in the TO SLOT screen of the D-I/O Input Setup Section.

To operate MMC, set the MMC PORT to ‘MIDI’ in the MIDI SETUP screen of the TANDEM MASTER unit. In this case, the MIDI channel of MMC should be set at the same MIDI channel of MMC to be received on the BRC.

To send/receive the MIDI messages, set the PORT of Gen.Rx and Gen.Tx to ‘MIDI’ in the MIDI SETUP screen. For the TANDEM SLAVE unit, set the SEND/RECEIVE of the various MIDI messages to ‘THRU.’

For MTC reception on the WR-DA7, set MTC PORT to ‘MIDI’ in the MIDI SETUP screen of the TANDEM Master unit.

To obtain the MTC timecode display on the LCD screen set the TIME BASE to ‘MTC’ in the AUTOMATION EXECUTE screen of the Automation SETUP SECTION.

(To use SMPTE timecode connect the WR-SMPTE card, and set the TIME BASE to ‘SMPTE.’)

ADAT setting

For ADAT wordclock setting, connect a Sync cable from the BRC and turn on the power supply. The setting is automatically set to ‘EXT’ and the ADAT functions as a SLAVE to the BRC.

The ADAT ID numbers are automatically set in the order of the SYNC cable connections from SYNC OUT to SYNC IN.

The power supply of each ADAT should be turned on first, then turn ON the power supply of the BRC.

To use the digital input of the ADAT, the DIGITAL IN button should be selected S on the ADAT’s front panel.

During ADAT playback if ALL INPUT is ON there will be no playback. ALL INPUT must be turned OFF.

BRC setting(BRC as the wordclock master)

Select the Fixed Mode when the BRC is used as the wordclock master and set the sampling rate to 48kHz. When the sampling rate is set to 44.1kHz select the Variable Mode and press the PITCH DOWN switch to a setting of-147cent ( ‘44.1’ display).

To obtain a through output of the MIDI message received on the BRC, press the BRC’s MIDI/UTIL button repeatedly to display the MIDI ECHO screen and select the ON setting.

For setting MTC, display the MIDI screen by pressing the GEN SYNC button to select a setting of ‘MTC.’ Press the EDIT button to exit the edit mode then, press the GEN SYNC button to enable sync generation.

For setting SMPTE, press the GEN SYNC button to display SMPTE: and use the UP/DOWN to select ‘-10dB’ then, press the EDIT button to exit the edit mode press the GEN SYNC switch to enable SMPTE sync the LED will light.

To obtain a timecode output from the BRC even during FF/REW operations of the ADAT, obtain a display of 8: Output Rew/FF SMPTE & MTC: for ‘ON’ in MIDI/UTIL setting of the BRC.

21

Page 20
Image 20
Teac WR-DA7 manual Adat setting, BRC settingBRC as the wordclock master