Basic Test Procedures
3–10 CTS 710 SONET Test Set User Manual
2. To check the LTE response to a Section B1 error, set up the
upstream CTS 710 as follows:
Press Menu
Button Select Menu
Page Highlight
Parameter Select Choice
TEST SETUPS RECALL
INSTRUMENT
SETUPS
DEFAULT
FACTORY
SETTINGS
Recall Setup
TRANSMIT TRANSMIT
SETTINGS Transmit Rate STS-1
Tx/Rx Settings Coupled
TRANSMIT ERRORS &
ALARMS Error Type Section B1 BIP
Error Rate set to 1.0E–5
RESULTS MAIN RESULTS none Errors