Setting Pointers and Changing Timing
CTS 710 SONET Test Set User Manual 3–147
Continuous Pointer Movement
To make repetitive pointer movements:
1. Specify the type of pointer control and movement rate as follows:
Press Menu
Button Select Menu
Page Highlight
Parameter Select Choice
Pointer Control Continuous
Pointer Rate Max 48 ms
(Mapping = VT1.5
Async only)
Max 2ms
Min 10000ms
Default 50ms
USER DEFINED
HSelect Max 48ms to move the pointer one location every 48
milliseconds.
HSelect Max 2ms to move the pointer one location every
sixteen frames.
HSelect Min 10000ms to move the pointer location one
location every 10 seconds.
HSelect Default 50ms to move the pointer one location every
50 ms.
HSelect USER DEFINED to set continuous pointer movement
at a rate different from the preset choices.
2. Select USER DEFINED to set the pointer movement to a value
different from the preset choices.
Selecting USER DEFINED places the CTS 710 into Edit Mode.
Now you can set the rate to the exact value you want, with 1 ms
resolution. The minimum rate is 1 ms. The maximum rate is
10000 ms.
Setting Pointers and Changing Timing
CTS 710 SONET Test Set User Manual 3–147
Continuous Pointer Movement
To make repetitive pointer movements:
1. Specify the type of pointer control and movement rate as follows:
Press Menu
Button Select Menu
Page Highlight
Parameter Select Choice
Pointer Control Continuous
Pointer Rate Max 48 ms
(Mapping = VT1.5
Async only)
Max 2ms
Min 10000ms
Default 50ms
USER DEFINED
HSelect Max 48ms to move the pointer one location every 48
milliseconds.
HSelect Max 2ms to move the pointer one location every
sixteen frames.
HSelect Min 10000ms to move the pointer location one
location every 10 seconds.
HSelect Default 50ms to move the pointer one location every
50 ms.
HSelect USER DEFINED to set continuous pointer movement
at a rate different from the preset choices.
2. Select USER DEFINED to set the pointer movement to a value
different from the preset choices.
Selecting USER DEFINED places the CTS 710 into Edit Mode.
Now you can set the rate to the exact value you want, with 1 ms
resolution. The minimum rate is 1 ms. The maximum rate is
10000 ms.