8.6 Input Multiplexer

8.6 Input Multiplexer

T

= 25°C, AV

= 3.3 V, DV = 3.3 V, f

S

= 48 kHz, 20-bit I2S mode

 

A

DD

DD

 

 

 

 

 

 

PARAMETER

 

 

TEST CONDITIONS

MIN TYP MAX

UNIT

 

 

 

 

 

 

 

Input impedance

 

 

 

 

20

k

 

 

 

 

 

 

 

Crosstalk

 

 

 

 

85

dB

 

 

 

 

 

 

Full-scale input voltage range

 

 

 

1.7

VPP

8.7 DAC Interpolation Filter

TA = 25°C, AVDD = 3.3 V, DVDD = 3.3 V, fS = 48 kHz, 20-bit I2S mode

All terms characterized by frequency are scaled with the normal mode sampling frequency, fS. See Figure 8−5 and Figure 8−6 for performance curves of the DAC digital filter.

PARAMETER

TEST CONDITIONS

MIN TYP

MAX

UNIT

 

 

 

 

 

Pass band

 

0.0

20.0

kHz

 

 

 

 

 

Pass-band ripple

 

±0.005

 

dB

 

 

 

 

 

Stop band

 

24.1

 

kHz

 

 

 

 

 

Stop-band attenuation

28.8 kHz to 3 MHz

75

 

dB

 

 

 

 

 

Group delay

 

700

 

s

 

 

 

 

 

Amplitude − dB

0

R

−20

−40

−60

−80

−100

0

fs/2

1 fs

2 fs

3 fs

4 fs

5 fs

 

 

 

f − Frequency − Hz

 

 

Figure 8−5. DAC Filter Overall Frequency Characteristics

 

0.1

 

 

 

 

 

− dB

0.05

 

 

 

 

 

 

 

 

 

 

 

Amplitude

0

 

 

 

 

 

−0.05

 

 

 

 

 

 

 

 

 

 

 

 

−0.1

 

 

 

 

 

 

0

0.1 fs

0.2 fs

0.3 fs

0.4 fs

0.5 fs

 

 

 

f − Frequency − Hz

 

 

Figure 8−6. DAC Digital Filter Pass-Band Ripple Characteristics