Texas Instruments TAS3002 Analog-to-DigitalConverter, 4. ADC High-PassFilter Characteristics

Models: TAS3002

1 54
Download 54 pages 10.85 Kb
Page 47
Image 47
Figure 8−4. ADC High-Pass Filter Characteristics

Amplitude − dB

0.008

0.006

0.004

0.002

0

−0.002

0

0.1 fs

0.2 fs

0.3 fs

0.4 fs

0.5 fs

f − Frequency − Hz

Figure 8−3. ADC Digital Filter Pass-Band Characteristics

 

0.2

 

 

 

 

 

0

 

 

 

 

dB

−0.2

 

 

 

 

 

 

 

 

 

Amplitude

−0.4

 

 

 

 

−0.6

 

 

 

 

 

 

 

 

 

 

−0.8

 

 

 

 

 

−1

 

 

 

 

 

0

1 fs

2 fs

3 fs

4 fs

 

 

 

f − Frequency − Hz

 

 

Figure 8−4. ADC High-Pass Filter Characteristics

8.5 Analog-to-Digital Converter

TA = 25°C, AVDD = 3.3 V, DVDD = 3.3 V, fS = 48 kHz, 20-bit I2S mode

All terms characterized by frequency are scaled with the chosen sampling frequency, fS.

PARAMETER

TEST CONDITIONS

MIN TYP MAX

UNIT

 

 

 

 

SNR (EIAJ)

A weighted

93

dB

 

 

 

 

Dynamic range

−60 dB, 1 kHz

88

dB

 

 

 

 

Signal to (noise + distortion) ratio

−1 dB, 1 kHz, 20 Hz to 20 kHz

82

dB

 

 

 

 

Power supply rejection ratio

1 kHz (see Note 3)

50

dB

 

 

 

 

Idle channel tone rejection

 

+110

dB

 

 

 

 

Intermodulation distortion

 

−80

dB

 

 

 

 

ADC crosstalk

 

−93

dB

 

 

 

 

Overall ADC frequency response

20 Hz to 20 kHz

±0.1

dB

 

 

 

 

Gain error

 

5%

 

 

 

 

 

Gain matching

 

±0.02

dB

 

 

 

 

NOTE 3: Measured with a 50-mV peak sine curve.

8−3

Page 47
Image 47