10.8.42.2

SMART Read Attribute thresholds

 

 

 

 

 

 

 

COMMAND CODE

1 0 1 1 0 0 0 0

REGISTER

 

 

 

REGISTER SETTING

NORMAL COMPLETION

 

DR

 

DRIVE No.

no change

 

CY

 

 

C24Fh

no change

 

HD

 

 

 

no change

 

SN

 

 

 

no change

 

SC

 

 

 

 

 

FT

 

 

D1h

no change

This command transfers attribute thresholds of the drive as 512 byte data.

Upon receipt of the command, the drive sets BSY, sets SMART data on the buffer, then, sets DRQ, resets BSY and issues an interrupt to report to the host that data transfer is ready.

Byte

Descriptions

0-1

Data structure revision number

2-361

1st-30th Individual attribute threshold data

362-510

Reserved

511

Data structure checksum

BYTE 0-1: Data structure revision number

The value for this byte is 0010h.

BYTE 2-361: Individual attribute threshold data

Individual attribute threshold data consists of 12 byte data. ( See the following fig.)

Byte

Description

0

Attribute ID number 01h - FFh

1Attribute Threshold 00h= Always passed 01h= Minimum value FDh= Maximum value FEh, FFh= Not in use

2-11 Reserved

BYTE 362-510: Reserved

BYTE 511: Data structure checksum

The checksum of the first 511 byte.

Toshiba Corporation Digital Media Network Company

Page 107 of 157

© 2005, Copyright TOSHIBA Corporation All Rights Reserved