360050398
10.8.17 Download Microcode (92h)
COMMAND CODE | 1 0 0 0 0 0 1 0 | REGISTER | |
| REGISTER SETTING | NORMAL COMPLETION | |
DR | drive number | no change | |
CY |
|
| 00h |
HD |
|
| no change |
SN | number of sector(high order) | 00h | |
SC | number of sector(low order) | 00h | |
FT | subcommand code | no change |
This command enables the host to alter the device’s microcode. The data transferred using the DOWNLOAD MICROCODE command is vendor specific.
All transfers shall be an integer multiple of the sector size. The size of the data transfer is determined by the contents of the Sector Number register and the Sector Count register. The Sector Number register shall be used to extend the Sector Count register to create a
The Features register shall be used to determine the effect of the DOWNLOAD MICROCODE command. The values for the Features register are:
−07h - save downloaded code for immediate and future use. This feature(07h) is supported. All other values are reserved.
Toshiba Corporation Digital Media Network Company
Page 70 of 157
© 2005, Copyright TOSHIBA Corporation All Rights Reserved