WORD 47:
bit 15 - 8 shall be set to 80h
bit 7 - 0 Maximum number of sectors that can be transferred per interrupt on READ/WRITE MULTIPLE commands.
The default value for this WORD is 8010h.
WORD 48: Reserved
WORD 49: Capabilities
bit
bit 13 1=Standby timer value shall be as specified in
Reserved (For advanced PIO mode support) 1=IORDY is supported.
1=IORDY function can be disabled. 1=LBA supported
1=DMA supported Reserved
The value for this WORD is 2F00h.
WORD 50: Capabilities
bit 15 | 0 | (Fixed) |
bit 14 | 1 | (Fixed) |
bit | Reserved | |
bit 0 | 1=device has a minimum Standby timer value that is device specific. |
Standby timer value is set to 5 minutes or more. The value for this WORD is 4000h.
WORD 51: PIO data transfer cycle timing mode
bit 15- 8 | PIO data transfer cycle timing mode |
bit 7- 0 | Reserved |
The value returned in Bits
Note: For backwards compatibility with BIOS written before Word 64 was defined for advanced modes, a device reports in Word 51 the highest original PIO mode (i.e. PIO mode 0, 1, or 2) it can support.
The value for this WORD is 0200h.
WORD 52: Reserved
WORD 53: |
|
|
bit15- 3 | Reserved |
|
bit 2 | 1= the fields reported in word | 88 is valid |
bit 1 | 1= the fields reported in words 64~70 are valid | |
bit 0 | 1= the fields reported in words 54~58 are valid |
If the number of heads and sectors exceed the drive parameter, bit 0 and related WORD
WORD 54: Number of current cylinders defined by INITIALIZE DEVICE PARAMETERS command
WORD 55: Number of current heads defined by INITIALIZE DEVICE PARAMETERS command
WORD 56: Number of current sectors/track defined by INITIALIZE DEVICE PARAMETERS command
Toshiba Corporation Digital Media Network Company
Page 85 of 157
© 2005, Copyright TOSHIBA Corporation All Rights Reserved