10.8.42.7 SMART Write Log Sector

COMMAND CODE

1 0 1 1 0 0 0 0

REGISTER

 

REGISTER SETTING

NORMAL COMPLETION

DR

DRIVE No.

no change

CY

 

C24Fh

no change

HD

 

 

no change

SN

Log Sector Address

no change

SC

Number of sectors to write

00h

FT

 

D6h

no change

This command writes an indicated number of 512 byte data sectors to the indicated log.

10.8.42.8 SMART Enable Operations

COMMAND CODE

 

1 0 1 1 0 0 0 0

REGISTER

 

REGISTER SETTING

NORMAL COMPLETION

DR

 

DRIVE No.

no change

CY

 

 

C24Fh

no change

HD

 

 

 

no change

SN

 

 

 

no change

SC

 

 

 

no change

FT

 

 

D8h

no change

This command enables access to all SMART capabilities of the drive. Prior to receipt of this command, Parameters for drive failure prediction are neither monitored nor saved by the drive. The state of SMART (either enabled or disabled) will be preserved by the drive across power cycles. Once enabled, the receipt of subsequent SMART ENABLE OPERATIONS commands don’t affect any of the parameters for drive failure prediction.

Upon receipt of this command from the host, the drive sets BSY, enables SMART capabilities and functions, clears BSY and asserts INTRQ.

Toshiba Corporation Digital Media Network Company

Page 121 of 157

© 2005, Copyright TOSHIBA Corporation All Rights Reserved