Format table consists of the number of sectors ( 16 bits ) per track . Upper byte represents sector number, and lower byte represents format type.
The drive supports only 00H format type. Intending to maintain compatibility with previous models, the drive accepts any format type, but the function will not change.
Sector interleave is always set to one regardless of sector sequence in the format table. Data subsequent to format table are handled as “Don't care”.
FORMAT TABLE ( FIRST 86 BYTES ) (Ex. 43 logical sector mode)
0001, 0002, 0003, 0004, 0005, 0006, 0007, 0008, 0009, 0013, 0015, 0016, 0017, 0018,.0019, 001A,.......0029, 002A, 002B
DON’T CARE ( 426 BYTES ATTACHED )
0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, 0000, ........... 0000, 0000, 0000.
10.8.13 Seek | (7xh) |
| |||
|
|
|
|
| |
| COMMAND CODE | 0 1 1 1 X X X X | REGISTER | ||
|
|
| REGISTER SETTING | NORMAL COMPLETION | |
| DR |
| drive no. | no change | |
| CY |
| cylinder to seek | no change | |
| HD |
| head to seek | no change | |
| SN |
|
|
| no change |
| SC |
|
|
| no change |
| FT |
|
|
| no change |
| LBA |
| address to seek | no change |
This command moves the R/W heads to the cylinder specified in the task files. The drive sets BSY and starts seek operation. After the completion of a seek operation, the drive asserts DSC8 , negates BSY , and return the interrupt.
If CY, HD and SN registers show invalid address, “ID Not Found” error is reported and no seek operation shall be executed. All commands related to data access possess Implied Seek function and don't need this command.
10.8.14 Toshiba Specific
COMMAND CODE 1 0 0 0 X X X X
1 0 0 1 1 0 1 0
1 1 1 1 0 0 0 0
1 1 1 1 0 1 1 1
1 1 1 1 1 0 1 X
1 1 1 1 1 1 X X
These commands are only for factory use. Host must not issue them.
8
Toshiba Corporation Digital Media Network Company
Page 67 of 157
© 2005, Copyright TOSHIBA Corporation All Rights Reserved