Protocol
1. Select 9-bit UART mode on the master and slave controllers.
2. Set the SC0MOD0<WU> bit on each slave controller to 1 to enable data receiving.
3. The master controller transmits one-frame data including the 8-bit select code for
the slave controllers. The MSB (Bit8) <TB8> is set to “1”.
4. Each slave controller receives the above frame. If it matches with own select code,
clears <WU> bit to “0”.
5. The master controller transmits data to the specified slave controller whose
SC0MOD0<WU> bit is cleared to “0”. The MSB (Bit8) <TB8> is cleared to “0”.
6. The other slave controllers (whose <WU> bits remain at 1) ignore the received
data because their MSB (Bit8 or <RB8>) are set to “0”, disabling INTRX0
interrupts. The slave controller (<WU> bit = “0”) can transmit data to the master
controller, and it is possible to indicate the end of data receiving to the master
controller by this transmission.
Start Bit0 123456
Select code of slave controller
7Stop
8
“1”
Start Bit0 123456
Data
7Stop
Bit8
“0”