TMP92CM22

2007-02-16

92CM22-218

4.2 AC Characteristics

4.2.1 Basis Bus Cycle

Read cycle

Vcc = 3.3 ± 0.3 V/fc = 4 to 40 MHz/Ta = 40 to 85°C

No. Parameter Symbol Min Max

fSYS =

20 MHz

(fc = 40 MHz)

fSYS =

125 kHz

(fc = 4 MHz) Unit

1 OSC period (X1/X2) tOSC 25 250 25 250 ns
2 System clock period (= T) tCYC 50 8000 50 8000 ns
3 CLKOUT low width tCL 0.5T 15 10 3985 ns
4 CLKOUT high width tCH 0.5T 15 10 3985 ns
5-1 A0 to A23 valid
D0 to D15 input at 0 waits tAD 2.0T 30 70 15970 ns
5-2 A0 to A23 valid
D0 to D15 input at 1 wait tAD3 3.0T 30 120 23970 ns
6-1 RDfall
D0 to D15 input at 0 waits tRD 1.5T 30 45 11970 ns
6-2 RDfall
D0 to D15 input at 1 wait tRD3 2.5T 30 95 19970 ns
7-1 RD low width at 0 waits tRR 1.5T 20 55 11980 ns
7-2 RD low width at 1 wait tRR3 2.5T 20 105 19980 ns
8 A0 to A23 valid RD fall tAR 0.5T 15 10 3985 ns
9 RD fall CLKOUT fall tRK 0.5T 20 5 3980 ns
10 A0 to A23 valid D0 to D15 hold tHA 0 0 0 ns
11 RD rise D0 to D15 hold tHR 0 0 0 ns
12 WAIT setup time tTK 15 15 15 ns
13 WAIT hold time tKT 5 5 5 ns

Write cycle

Vcc = 3.3 ± 0.3 V/fc = 4 to 40 MHz/Ta = 40 to 85°C

No. Parameter Symbol Min Max

fSYS =

20 MHz

(fc = 40 MHz)

fSYS =

125 kHz

(fc = 4 MHz) Unit

1 OSC period (X1/X2) tOSC 25 250 25 250 ns
2 System clock period (= T) tCYC 50 8000 50 8000 ns
3 CLKOUT low width tCL 0.5T 15 10 3985 ns
4 CLKOUT high width tCH 0.5T 15 10 3985 ns
5-1 D0 to D15 valid WRxxrise at 0 waits tDW 1.25T 35 28 9965 ns
5-2 D0 to D15 valid WRxxrise at 1 wait tDW3 2.25T 35 78 17965 ns
6-1 WRxx low width at 0 waits tWW 1.25T 30 33 9970 ns
6-2 WRxx low width at 1 wait tWW3 2.25T 30 83 17970 ns
7 A0 to A23 valid WR fall tAW 0.5T 15 10 3985 ns
8 WRxx fall CLKOUT fall tWK 0.5T 20 5 3980 ns
9 WRxx rise A0 to A23 hold tWA 0.25T 5 8 1995 ns
10 WRxx rise D0 to D15 hold tWD 0.25T 3 10 1997 ns
11 WAIT setup time tTK 15 15 15 ns
12 WAIT hold time tKT 5 5 5 ns
13 RD rise D0 to D15 output tRDO 0.5T 5 20 3995 ns
AC condition
Output : High = 0.7Vcc, Low = 0.3Vcc, CL = 50 pF

Input : High = 0.9Vcc, Low = 0.1Vcc