TP-Link TL-SL5428E manual UDP Port, User, Retry, Timeout

Models: TL-SL5428E

1 259
Download 259 pages 46.72 Kb
Page 203
Image 203

Figure 12-8 Notification Config

The following entries are displayed on this screen:

¾Create Notification

IP Address:

Enter the IP Address of the management Host.

UDP Port:

Enter the number of the UDP port used to send notifications.

 

The UDP port functions with the IP address for the notification

 

sending. The default is 162.

User:

Enter the User name of the management station.

Security Model:

Select the Security Model of the management station.

Security Level:

Select the Security Level for the SNMP v3 User.

 

noAuthNoPriv: No authentication and no privacy security

 

level are used.

 

authNoPriv: Only the authentication security level is used.

 

authPriv: Both the authentication and the privacy security

 

levels are used.

Type:

Select the type for the notifications.

 

Trap: Indicates traps are sent.

 

Inform: Indicates informs are sent. The Inform type has a

 

higher security than the Trap type.

Retry:

Specify the amount of times the switch resends an inform

 

request. The switch will resend the inform request if it doesn’t

 

get the response from the management station during the

 

Timeout interval, and it will terminate resending the inform

 

request if the resending times reach the specified Retry times.

Timeout:

Specify the maximum time for the switch to wait for the

 

response from the management station before resending a

 

request.

¾Notification Table

195

Page 203
Image 203
TP-Link TL-SL5428E manual UDP Port, User, Retry, Timeout