Model Number Description

AReturn w/o Statitrac CV Only C Return w/ VFD w/ Bypass w/

Statitrac

E Return w/ VFD w/o Bypass w/ Statitrac

DIGIT 18 — EXHAUST/RETURN FAN MOTOR SELECTION

0None D 7.5 Hp E 10 Hp F 15 Hp G 20 Hp H 25 Hp J 30 Hp K 40 Hp L 50 Hp M 60 Hp

DIGIT 19 — EXHAUST/RETURN RPM SELECTION

0None

3300

4400

5500

6600

7700

8800

9900 A 1000 B 1100 C 1200 D 1300 E 1400

DIGIT 20 — SYSTEM CONTROL SELECTION

1Constant Volume (Zone Temperature Control)

2VAV w/o Inlet Guide Vanes (Discharge Air Control)

3VAV w/ Inlet Guide Vanes (Discharge Air Control)

4VFD Supply w/o Bypass (Discharge Air Control)

5VFD Supply w/Bypass (Discharge Air Control)

DIGIT 21 — FRESH AIR AND ECONOMIZER OPTIONS/ CONTROLS

A0 - 25 % Motorized Damper

BEcon w/Dry Bulb

CEcon w/Reference Enthalpy

DEcon w/Comparative Enthalpy

EEcon w/Fresh Air Measure /Dry Bulb

FEcon w/ Fresh Air Measure /Ref Enth

GEcon w/Fresh Air Measure /Comp Enth

HEcon w/DCV /Dry Bulb

JEcon w/DCV /Ref Enth

KEcon w/DCV /Comp Enth

DIGIT 22 — DAMPER OPTION

0Standard

1Low Leak

2Ultra Low Leak

DIGIT 23 — PRE COOLING COIL FILTER SELECTION

02" High Efficiency Throw Away

12" Throw Away Rack / Less Filters

290 - 95%, Bag Filters w/ Pre Filters

3Bag Filter Rack / Less Filters

490 - 95%, Cartridge Filters w/ Pre Filters

5Cartridge Rack / Less Filters

690 - 95% Low PD Cartridge w/ Pre Filters

7Low PD Cartridge Rack / Less Filters

DIGIT 24 — BLANK SECTION APPLICATION OPTIONS

0 None

A90 - 95% Bag w/Pre Filters

B90 - 95% Low PD Cartridge w/ Pre Filters

C90 - 95%, Cartridge Filters w/ Pre Filters

D90 - 95% Hi Temp Cartridge w/ Pre Filters

EHEPA w/Pre Filters

FHi Temp HEPA w/Pre Filters

DIGIT 25 — FUTURE

DEVELOPMENT

0

DIGIT 26 — UNIT MOUNTED POWER CONNECTION SELECTION

ATerminal Block

BNon Fused Disconnect

CNon Fused Disconnect w/ Pwrd conv outlet

DCircuit Breaker w/ SCWR

ECkt Brkr w/ SCWR/ Pwrd conv outlet

DIGIT 27 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 28 — COIL/DRAIN PAN

DNo Drain Pan

EGalvanized Drain Pan

FCooling Coil - Galv DP

GCooling Coil - Stnls Steel DP

DIGIT 29 — CHILLED WATER COIL VALVE

0 None

A1.5" Cooling Valve

B2" Cooling Valve

C2.5" Cooling Valve

D3" Cooling Valve

DIGIT 30 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 31 — (FUTURE

DEVELOPMENT)

0 None

DIGIT 32 — HIGH DUCT TEMPERATURE THERMOSTAT

0None

1High Duct Temp Thermostat

DIGIT 33 — REMOTE HUMAN INTERFACE

0None

1RHI & IPCB

2IPCB

DIGIT 34 — MODULE OPTIONS

0 None

A0-5 Volt GBAS

B0-10 Volt GBAS

C0-5 / 0-10 Volt GBAS

FLCI

DVentilation Override

G0-5 Volt GBAS / Ventilation Override

H0-10 Volt GBAS / Ventilation Override

J 0-5 / 0-10 V GBAS / Ventilation

Override

L LCI / Ventilation Override

DIGIT 35 — ZONE SENSOR OPTION

0 None

ADual Setpoint w/Man/Auto Changeover

BDual Stpt w/Man/Auto Chgovr & Sys Lights

CRoom Sensor w/Timed Override & Cancel

DRoom Snsr w/TO & Cancel & Local Stpt Adj

ECV Programmable Night Setback

FVAV Programmable Night Setback

GVAV w/System Lights

DIGIT 36 — AGENCY APPROVAL OPTION

0None

1UL/CSA

32

RT-PRC031-EN

Page 32
Image 32
Trane RT-PRC031-EN manual Model Number Description, Digit 20 System Control Selection