Performance Data — Supply Fan with Inlet Guide Vanes

Table 18 Supply Fan Performance STANDARD CFM — Casing A (25")

CFM

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std.

6.25

6.50

6.75

7.00

7.25

7.50

7.75

8.00

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16000

1657

24.15

1678

24.95

1697

25.68

1719

26.55

1739

27.34

1760

28.16

1780

28.98

1803

29.88

17000

1694

26.21

1715

27.05

1736

27.92

1755

28.73

1775

29.56

1795

30.43

1815

31.32

1833

32.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18000

1734

28.48

1754

29.36

1773

30.16

1794

31.12

1813

31.98

1833

32.88

1853

33.82

1870

34.66

19000

1776

30.93

1794

31.76

1814

32.74

1833

33.62

1852

34.53

1871

35.48

1889

36.38

1908

37.32

20000

1820

33.62

1838

34.50

1856

35.41

1874

36.35

1892

37.26

1910

38.18

1929

39.21

1946

40.12

21000

1869

36.64

1885

37.52

1902

38.42

1919

39.35

1937

40.31

1954

41.30

1971

42.24

1988

43.21

22000

1918

39.84

1934

40.78

1951

41.75

1967

42.67

1983

43.61

1999

44.58

 

 

 

 

23000

1968

43.32

1984

44.25

1999

45.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

Std.

8.25

8.50

8.75

9.00

 

 

 

 

 

 

 

 

Air

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16000

1827

30.81

1849

31.71

1872

32.64

1895

33.60

 

 

 

 

 

 

 

 

17000

1853

33.00

1873

33.91

1892

34.76

1914

35.77

 

 

 

 

 

 

 

 

18000

1888

35.53

1906

36.42

1925

37.33

1944

38.28

 

 

 

 

 

 

 

 

19000

1927

38.29

1945

39.22

1962

40.11

1981

41.10

 

 

 

 

 

 

 

 

20000

1964

41.06

1983

42.11

1999

43.02

 

 

 

 

 

 

 

 

 

 

21000

2005

44.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.Supply fan performance table includes internal resistance of air handler. For total static pressure determination, system external static pressure must be added to appropriate component sp drops (chilled water coil, filters, optional economizer, optional heating system).

2.Maximum SP leaving the air handler is 5.5" H20 positive.

(i)Outlined area indicates nonstandard BHP or RPM selections. Contact a local Trane representative for more information.

(ii)Outlined area indicates nonstandard BHP or RPM selections. Contact a local Trane representative for more information.

52

RT-PRC031-EN

Page 52
Image 52
Trane RT-PRC031-EN manual Performance Data Supply Fan with Inlet Guide Vanes