Applications Considerations

Table 1 Supply Airflow Configuration

 

 

 

 

With Bag

With

 

 

 

 

Acceptable

Final

Cartridge

With HEPA

Cabinet Configuration

Supply Airflow Discharge Direction

Type

Application

Filters

Final Filters

Final Filters

 

 

 

 

 

 

 

Standard Length

Downflow - Standard Option

Cooling Only

Yes

No

No

No

 

 

 

 

 

 

 

Standard Length

Horizontal - Right Side - Standard Option

Cooling Only

Yes

No

No

No

 

 

 

 

 

 

 

Standard Length

Horizontal - Left Side - Field Convertible

Cooling Only

Field

No

No

No

 

 

 

Convert

 

 

 

 

 

 

 

 

 

 

Standard Length

Downflow - Standard Option

Gas, Electric, Steam,

Yes

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Standard Length

Horizontal - Right Side - Standard Option

Gas, Electric, Steam,

Yes

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Standard Length

Horizontal - Left Side - Field Convertible

Gas, Electric, Steam,

No

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Four Foot Blank Section

Downflow - Standard Option

Cooling Only

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

Four Foot Blank Section

Horizontal - Right Side - Standard Option

Cooling Only

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

Four Foot Blank Section

Horizontal - Left Side - Field Convertible

Cooling Only

Field

Yes

Yes

Yes

 

 

 

Convert

 

 

 

 

 

 

 

 

 

 

Four Foot Blank Section

Downflow - Standard Option

Gas, Electric, Steam,

No

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Four Foot Blank Section

Horizontal - Right Side - Standard Option

Gas, Electric, Steam,

No

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Four Foot Blank Section

Horizontal - Left Side - Field Convertible

Gas, Electric, Steam,

No

No

No

No

 

 

Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Eight Foot Blank Section

Downflow - Standard Option

Cooling Only, Steam

Yes

Yes

Yes

Yes

 

 

Heat, Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Eight Foot Blank Section

Horizontal - Right Side - Standard Option

Cooling Only, Steam

Yes

Yes

Yes

Yes

 

 

Heat, Hot Water Heat

 

 

 

 

 

 

 

 

 

 

 

Eight Foot Blank Section

Horizontal - Left Side - Field Convertible

Cooling Only, Steam

Field

Yes

Yes

Yes

 

 

Heat, Hot Water Heat

Convert

 

 

 

 

 

 

 

 

 

 

Eight Foot Blank Section

Downflow - Standard Option

Gas* or Electric

Yes

No

High

High

 

 

 

 

 

Temperature

Temperature

 

 

 

 

 

 

 

Eight Foot Blank Section

Horizontal - Right Side - Standard Option

Gas* or Electric

Yes

No

High

High

 

 

 

 

 

Temperature

Temperature

 

 

 

 

 

 

 

Eight Foot Blank Section

Horizontal - Left Side - Field Convertible

Gas* or Electric

Field

No

High

High

 

 

 

Convert

 

Temperature

Temperature

 

 

 

 

 

 

 

Table 2 Return Airflow Configuration

AirflowConfig

 

Exhaust Fan

 

Return Fan

 

Exhaust Fan VFD

No VFD

Return Fan VFD

No VFD

 

 

 

 

 

Vertical

Yes

Yes

Yes

Yes

 

 

 

 

 

Horizontal - Right

Yes

Yes

Yes

Yes

 

 

 

 

 

Horizontal - Left

No

Field Convert

No

No

 

 

 

 

 

Horizontal - End

Yes

Yes

No

No

 

 

 

 

 

24

RT-PRC031-EN

Page 24
Image 24
Trane RT-PRC031-EN manual Supply Airflow Configuration, Return Airflow Configuration, With Bag, Cartridge, Type