VII. g - CUSTOMER SERVICE PARAMETERS:

VII. INTELA-TRAUL®(continued)

VII. g - CUSTOMER SERVICE PARAMETERS:

Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can use either the up or down arrow keys to scroll through the options.

Thermostat Set Point High*

Defrost Lockout 2

Thermostat Set Point Low

Defrost Lockout 3

Temperature Scale*

Defrost Lockout 4

Audible Alarm Style*

Dew Point Compensation Factor*

Time (24-hour clock)*

Room Temperature Offset

Date (month - day - year)*

Evaporator Coil Sensor

Daylight Savings *

Discharge Line Sensor

Defrost Lockout 1

Start Manual Defrost

*Available on Hot Food units.

VII. h - ADJUSTING THE THERMOSTAT SET POINT HIGH:

This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will range from -3°F to 0° F (-19°C to -18°C) and refrigerators will range from 36° F to 40° F (2° C to 4° C) for this parameter setting. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so. Note: Set Point Low and Set Point High cannot be set to the same temperature. There will be at least 1-2 degree difference between the two settings.

Follow the instructions to enter the customer access code on page 11. When the control

display reads *Available on Hot Food units.VII. h - ADJUSTING THE THERMOSTAT SET POINT HIGH:Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Thermostat Set Point High. Press the set button SET .

Use the arrow keys Manual backgroundManual background to adjust the temperature to your desired setting. When the display shows the temperature you want press the set button SET .

The display will then read Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Thermostat Set Point High.

You can use the up or down arrow keys to scroll to the next parameter Manual backgroundManual background

 

 

 

))

 

 

 

or press the alarm cancel button to exit

 

 

) .