VIII. TROUBLE SHOOTING GUIDE

FIND YOUR PROBLEM HERE

 

REMEDY

 

 

 

 

1. Condensing unit fails to start.

a.

Check if cord & plug has been disconnected.

 

b.

Check INTELA-TRAUL®temperature setting.

 

 

 

 

2. Condensing unit operates for

a.

Are doors closing properly?

prolonged periods or continuously.

b.

Dirty condenser or filter. Clean properly.

 

c.

Evaporator coil iced. Needs to defrost. See

 

 

instructions for setting a manual defrost cycle

 

 

on page 16.

 

d.

Shortage of refrigerant, call service.

 

 

 

 

3. Food compartment is too warm.

a.

Check door(s) and gasket(s) for proper seal

 

b.

Perhaps a large quantity of warm food has

 

 

recently been added or the door was kept

 

 

open for a long period of time, in both

 

 

cases, allow adequate time for the cabinet

 

 

to recover its normal operating temperature.

 

c.

INTELA-TRAUL®setting too high, readjust

 

 

per instructions on page 12.

 

 

 

 

4. Food compartment is too cold.

a.

Perhaps a large quantity of very cold or frozen

 

 

food has recently been added. Allow adequate

 

 

time for the cabinet to recover its normal operating

 

 

temperature.

 

b.

Adjust the INTELA-TRAUL®to a warmer

 

 

setting, see page 13.

 

 

 

 

5. Condensation on the exterior surface.

a.

Check door alignment and gaskets for proper seal.

 

b.

Condensation on the exterior surface of the

 

 

unit is perfectly normal during periods of

 

 

high humidity. However, to alleviate the

 

 

condition, adjust the INTELA-TRAUL®

 

 

“Dewpoint Compensation Factor,” see page 18.

6. Compressor hums but does not start.

a.Call for service.