THEORY OF OPERATION, SPECIFICATIONS, AND INSTALLATION

5

 

2.0" (51mm)

2.0" (51mm)

2.0" (51mm)

F I G U R E 3: Built-in Installation

2.0" (51mm)

Unobstructed

Airflow

Fan

300 CFM (8.5 CMM)

Discharge to Ambient

4.0" (102 mm)

Unobstructed

Airflow

Notes:

1: Must be included by contractor

F I G U R E 4: Installation Near Open Heat Source

Built-In Installation (Figure 3)

TurboChef ovens are designed to be installed on a countertop or table. They are not intended for built-in or enclosed installation.

“Built-in or enclosed installation” is defined as installing an oven in any structure that surrounds the oven by five sides (i.e., top/rear/side panels and base).

If installation must be “built in,” the operator must ensure the following:

†Minimum of 300 cfm (8.5 cmm) of supplement flow within the cabinet.

†Minimum clearances of 2′′ (51 mm) to every surface.

In addition, the operator will be responsible for compensating any extra time required to service the product due to removing the product for serviceability.

Page 13