SPS IDNet Wiring, Continued

Class B (string) Wiring

To connect addressable devices/detectors to the SPS IDNet using Class B wiring, read the following instructions.

1.Under AS1670.1 Class B wiring is allowed only for a maximum of 40 addressable devices.

2.A ferrite bead is required on the SPS IDNet cable.

3.On TB1, jumper B+ to A+, and jumper B- to A-.

4.Route wire from the B+, B- terminals to the devices.

The illustration below shows Class B wiring.

IDNet LINES TO DEVICES

(CLASS B / STYLE 4)

Ferrite bead required.

3

P1

 

2

B+ B- SHLD A+ A-

1

 

 

 

 

IDNet

 

Figure 5-10. Class B (string) Wiring

5-20

Page 88
Image 88
Tyco 4100U-S1 installation manual Class B string Wiring

4100U-S1 specifications

The Tyco 4100U-S1 is a sophisticated and robust fire alarm control panel known for its reliability and advanced features, catering primarily to commercial and industrial applications. This system represents the latest in fire safety technology, providing comprehensive protection for a wide range of environments.

One of the main features of the Tyco 4100U-S1 is its ability to support advanced signaling protocols. This capability allows for seamless communication with a variety of initiating devices and notification appliances, ensuring a rapid response to potential fire incidents. The control panel can accommodate a significant number of devices connected through its extensive loop options, enhancing its flexibility in larger installations.

The Tyco 4100U-S1 employs Intelligent Addressable Technology, which simplifies the installation process and reduces wiring complexity. Each device on the loop can communicate its status without needing additional wiring, making it easier to troubleshoot and maintain. This feature not only enhances the system's efficiency but also helps to minimize installation costs.

Another notable characteristic of the Tyco 4100U-S1 is its user-friendly interface. The panel is designed for ease of use, featuring intuitive controls and a clear display that allows users to monitor the system’s status quickly. The graphical interface provides real-time information about the system’s performance, giving users insight into alarm conditions and system health. This accessibility aids in training personnel and encourages adherence to safety protocols.

The Tyco 4100U-S1 also boasts advanced reporting capabilities, with programmable inputs and outputs that allow for detailed event logging and alarm management. The system can be configured to send notifications via various channels, ensuring that key personnel are alerted immediately in case of an emergency. This proactive approach to fire safety helps organizations mitigate risks and enhance response strategies.

In addition, the Tyco 4100U-S1 integrates well with other building management systems, supporting various communication protocols that facilitate interoperability. This integration capability allows users to create a comprehensive safety network that addresses not only fire protection but also other critical building functions.

Overall, the Tyco 4100U-S1 stands out in the fire alarm control panel market with its combination of advanced technology, intuitive design, and extensive flexibility, making it an ideal choice for organizations seeking robust fire safety solutions. Its features and characteristics ensure that it remains a top contender in enhancing life safety and property protection.