EXITING DATA CALLS

Under normal conditions, the radio enters the scan lockout mode and returns to the control channel after completion of a data call (transmit or receive). If, during a data call, one of the following conditions occurs, the data call is immediately terminated and the radio per-forms the desired function:

PTT activated.

Emergency declared by pressing the pre- programmed emergency button.

A group or system change.

SCAN LOCKOUT MODE

Following the transmission or reception of a data call, if scan is enabled, scanning will stop temporarily [two independent pre-programmed times (after receive data call and after transmit data call)]. During this time the scan indicator will flash to indicate that scan is enabled but temporarily suspended. This mode is normally exited when the pre-programmed time expires; however, the following actions will terminate the scan lockout mode before the timeout is completed.

The CLEAR button is pressed.

The PTT is pressed.

A group or system change.

Entering phone call mode.