1.Press MENU.

2.For Scan mode, select 2:SCAN OPTION / 1:CONVENTIONAL by rotating the VFO and pressing E.

3.Select the channel number of the stored frequency to be delayed by rotating the VFO and pressing E.

4.Select 2:DELAY and press E.

5.Rotate the VFO to select one of the delay periods and press E.

6.For Search mode, select 1:SERVICE OPTION / :CHAIN SEARCH / 3:DELAY by rotating the VFO and pressing E, then set to a delay period the same way as the Scan mode setting.

Note: The delay periods are as follows:

None: Delay feature off

1 sec.: Delays for 1 sec. before re-scanning

2 sec.: Delays for 2 sec. before re-scanning

4 sec.: Delays for 4 sec. before re-scanning

Infinite: Stays on until RSM is pressed

-2 sec.: Stays for 2 sec. only before re-scanning *

-5 sec.: Stays for 5 sec. only before re-scanning *

-10 sec.: Stays for 10 sec. only before re-scanning *

*Setting negative delay periods are useful if you are only interested in small seg- ments of conversations. For example: If you set a -5 second delay, you will only hear 5 seconds of the conversation and then the scanner will resume scanning, whether or not the conversation is finished.

Remember! You can also use or instead of rotating the VFO. Also instead of pressing E, you can press the VFO control.

Channel Lockout

You can lockout any channel so it is not checked during normal scanning. You can restore the channel to scanning when you wish.

Lockout in Hold Mode

1.Press /HOLD.

2.Select a channel.

a.Enter the channel number using the keypad.

b.Press /HOLD again.

–––OR –––

Rotate the VFO up or down to change the channel.

3.Press L/O to lockout the channel. L/O appears on the display.

C 001

141.5000 NFM

UNIDEN Group A

32

Page 36
Image 36
Uniden BC785D manual 001 141.5000 NFM Uniden Group a, Channel Lockout, Lockout in Hold Mode