Setting the Status Bit

M

[MENU] Program System

 

 

 

 

 

Select a Motorola Type I or II system

 

Edit Sys Option

 

Set Status Bit

 

Ignore — the scanner rounds all received ID’s down to the next interval of 16. The default setting is Ignore.

Yes — the scanner treats all received ID’s as unique ID’s.

Note: Motorola analog systems use talk group ID’s in multiples of 16. ID numbers that fall between these ID’s indicate special status flags for the system. This setting determines how the scanner will handle ID’s that are not multiples of 16.

Select your setting then press .

Setting End Code Operation

M

[MENU] Program System

 

Select a Motorola Type I or II system

 

Edit Sys Option

 

Set End Code

 

This setting determines how the scanner handles the transmission end code sent by most Motorola systems. Select your setting then press .

Yes — the scanner immediately returns to the control channel when it detects the end code.

Ignore — the scanner does not return to the control channel until the carrier drops.

Note: The default setting is Yes.

Setting I-Call Operation

ME

[MENU] Program System

 

Select a Motorola Type I, II or EDACS Wide/Narrow system

 

Edit Sys Option

 

Set I-Call

 

This setting determines how your scanner treats I-calls while ID Searching.

On — the scanner tracks I-calls.