10.13Supply Voltage Terminal Block - P/N 096810 Fuse - P/N 096809

Fuse 20 Amp - P/N 071489

1.Turn off the power to the steamer.

2.Remove the cover from the electrical compartment.

3.The terminal block is located on the back wall of the electrical compartment.

4.Using a flat blade screwdriver, disconnect the incoming wires from the top of the terminal block and the steamer wires from the lower portion of the terminal block.

5.With a wrench, remove the four 8-32 screws holding the terminal block to the back wall.

To Install:

6.Position the new terminal block on the back wall and install the four 8-32 screws using a wrench.

7.Using a flat blade screwdriver, connect the incoming wires to the top of the terminal block, and the steamer wires to the lower portion of the terminal block.

10.14Control Voltage Transformer P/N 121716

1.Turn off power to the steamer.

2.Remove the front lower panel.

3.Using an open ended wrench, remove the four 1/4-20 bolts holding the electrical compartment to the steamer table.

4.Disconnect the line side and the load side of the electrical wires from their respective terminals.

5.Using a socket wrench with an extension, remove the four 8-32 hex nut screws holding the transformer to the floor of the electrical compartment.

To Install:

6.Position the transformer in the electrical compartment.

7.Using a socket wrench with an extension, insert and tighten the four 8-32 hex nut screws.

8.Connect the load and line side terminals.

10.15Electrical Contactor

P/N 119811

1.Turn off power to the steamer.

2.Remove the front lower panel.

3.Using an open ended wrench, remove the four 1/4 - 20 bolts holding the electrical contactor to the electrical compartment.

4.Unplug the line side and the load side terminals of the contactor. Disconnect the control wires to the contactor.

5.Using a socket wrench and extension, remove the four 8-32 hex nut screws holding the contactor to the floor of the electrical compartment.

To Install:

6.Position the contactor in the electrical compartment.

7.Using a socket wrench and extension, insert and tighten the four 8-32 hex nut screws.

NOTE: The space is very restricted and it is helpful if the nutdriver has a magnetic head to hold the screw in position while it is being started.

8.Connect the load and line side terminals and the control wires.

NOTE. The following components and subassemblies are to be found in the upper portion of the steamer.

10.16 Timer Assembly

Timer Fastener Nut

P/N 100983

P/N 101145

1.Remove the four hex nuts which retain the control panel cover. Remove the cover.

2.Remove the knob from the timer. Under the knob is a hexagonal nut which holds the time mechanism to the steamer. Note that there is a flat on the timer shaft which corresponds to a frictional mounting hole on the knob.

3.From the left side, unplug the five terminals/wires (violet, gray, black, tan and white) from the timer mechanism and unplug the two black timer motor leads.

4.With an open-ended wrench, remove the hex nut holding the timer in place. The timer may then be removed from inside the compartment.

5.NOTE: Right below the timer shaft, the timer has a small plastic disk molded onto the case. There is a