Vanguard Managed Solutions MBDV41, MBDV37 Inspecting Burners, Remote Operation, Operating Blower

Models: MBDV41 MBDV37

1 40
Download 40 pages 61.76 Kb
Page 27
Image 27

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

REMOTE

OPERATION

Follow instructions included with the re- mote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions, page 26.

1. After lighting, let pilot flame burn for

about one minute. Turn gas control

knob on the control valve to ON posi-

tion. Turn variable control knob any-

where between HI and LO. Slide the

selector switch to the REMOTE po-

OPERATING

BLOWER

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

The GA3700 manual blower has an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

Blower Control Knob

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure

58.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If your pilot assembly does not meet these requirements:

sition. Note: The burner may light if

hand-held remote ON button was on

when selector switch was last turned

off. You can now turn the burners on

and off with the hand-held remote con-

trol unit.

IMPORTANT: Do not leave the se-

lector switch in the REMOTE posi-

tion when the pilot is not lit. This will

drain the battery.

OFF

ON

REMOTE

OFF

ON

Selector Switch in Remote Position

N

O

T

F

O

O

 

F

 

LIP

 

 

Gas Control

Knob in On

Position

turn fireplace off (seeTo Turn Off Gas to Appliance, page 26)

seeTroubleshooting, pages 31 through 34

Thermopile

3/8" to 1/2"

Pilot Burner

IMPORTANT: Be sure to press the

ON/OFF button on the hand-held re-

mote control unit for up to 3 seconds

to assure proper operation.

2. Press the ON/OFF button to turn the

burners on and off. When turning

burners off, the pilot will remain lit.

IMPORTANT: To turn the pilot off,

manually turn the gas control knob

on the heater to the OFF position.

Figure 57 - Setting the Selector Switch and Gas Control Knob for Remote Operation

1/8"

Thermocouple

Piezo

Ignitor

Figure 58 - Pilot Assembly

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incor- rectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.

Continued

106497