Radiance Direct Vent Gas Heater

5.Replace glass and stove front.

6.Restore gas to system and relight appliance accord- ing to Lighting Instructions on Page 30.

7.Leak check the system using a gas leak detector solution.

8.Relight the main burner in both the “HI” and “LO” po- sitions to verify proper burner ignition and operation.

Conversion is complete.

Table 2. Injector Orifice Size Matrix

Conversion to LP

 

 

 

 

 

 

 

 

Input (BTU/h)

 

Model

 

Kit #

 

Orifice

 

Part #

Minimum

 

Maximum

 

RADVT

 

20012729

 

1.75 mm

 

20012946

25,000

 

36,000

 

 

 

 

 

 

 

 

RADVTC

 

20012900

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion to Natural Gas

 

 

 

 

 

 

 

 

 

 

 

Input (BTU/h)

 

Model

 

Kit #

Orifice

Part #

Minimum

Maximum

 

RADVT

20012899

 

#31 / 0.120”

20006927

25,000

 

38,000

 

RADVTC

20012902

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3. Air Shutter Adjustment

 

Natural Gas

Natural Gas

LP

Model

 

High Altitude

 

RADVT/RADVC

1/2” Open

1/2” Open

1/2” Open

Table 4. High Altitude Orifice

[Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)]

 

 

 

Input (BTU/h)

Model

Orifice

Part #

Minimum

Maximum

RADVT/RADVTC

#33 / 0.113”

20012554

25,000

36,000

(Natural gas only)

 

 

 

 

*LP models do not need re-orificed up to 4500’ (1,370 m) above sea level.

20012697

39

Page 39
Image 39
Vermont Casting RADVTBD, RADVTMB, RADVTSG, RADVTCB Injector Orifice Size Matrix, Air Shutter Adjustment, High Altitude Orifice