6.Protocol 2 : without ID
6.1Set function listing
The PC can control the LCD Monitor for specific actions. The
Set-Function description:
Length: Total bytes of message = 5 ASCII (35H) excluding “CR”
Command: Function command code: One byte ASCII code
Value[1~3]: Three bytes ASCII that defines the value
Set-Function format:
Name
Byte Count
Bytes order
Length | Command | Value1 | Value2 | Value3 | CR |
1 Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte | 1 Byte |
1 | 2 | 3 | 4 | 5 | 6 |
All
| Name |
| Length | Command | Value1 | Value2 | Value3 | CR |
|
| Byte Count |
| 5 | 1 Byte | 1 Byte | 1 Byte | 1 Byte | 00D |
|
|
|
| |||||||
| Bytes order |
| 1 | 2 | 3 | 4 | 5 | 6 |
|
|
|
| |||||||
Example: Set |
|
|
|
| |||||
| Name |
| Length | Command | Value1 | Value2 | Value3 | CR |
|
| Byte Count |
| 5 | 6 | 0 | 0 | 0 | 00D |
|
|
|
| |||||||
| Bytes order |
| 1 | 2 | 3 | 4 | 5 | 6 |
|
Example: Set |
|
|
|
| |||||
| Name |
| Length | Command | Value1 | Value2 | Value3 | CR |
|
| Byte Count |
| 5 | 6 | 0 | 0 | 1 | 00D |
|
|
|
| |||||||
| Bytes order |
| 1 | 2 | 3 | 4 | 5 | 6 |
|
Example: Set Tint to 50 command (ASCII)
Name
Byte Count
Bytes order
Length | Command | Value1 | Value2 | Value3 | CR |
5 | ‘ | 0 | 5 | 0 | 00D |
1 | 2 | 3 | 4 | 5 | 6 |
LCD Monitor will send “+” (02Bh) and “CR” bytes to PC after receiving a valid command. LCD Monitor will send
Value Range: Three bytes ASCII value range
Command Code: Function command code in ASCII
CD4620/CD4220 set command table
Set Function | Length | Command | Command |
| Value Range | Comments |
|
| Code (ASCII) | Code (Hex) | (Three ASCII bytes) |
| |
Power | 5 | ! | 21 | 000: STBY | Controlled power status: ON or | |
|
|
|
| 001: ON | Standby | |
Input Select | 5 | “ | 22 | 000 : VGA |
| |
|
|
|
| 001 | : HDMI1 |
|
|
|
|
| 002 | : HDMI2 |
|
|
|
|
| 003 | : AV |
|
|
|
|
| 004 | : YPbPr |
|
|
|
|
| 005 | : |
|
Contrast | 5 | # | 23 | 000 ~ 100 |
|
ViewSonic CD4620 | 51 |
Downloaded From