5.Protocol 1 : with ID

5.1Command Description

Length:

Total Byte of Message excluding “CR”

TV ID

Identification for each of TV

 

Identify command type,

 

“s” (0x73h) : Set Command

 

“g” (0x67h) : Get Command

Command Type

“r” (0x72h) : Reply Command

 

“p” (0x70h) : RCU Pass-through

 

“+” (0x2Bh) : Valid command Reply

 

“-“ (0x2Dh) : Invalid command Reply

Command:

Function command code: One byte ASCII code

Value[1~3]:

Three bytes ASCII that defines the value

CR

0x0D

5.2Set-Function Listing

The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 11 bytes.

Set-Function description:

Length:

Total Byte of Message excluding “CR”

TV ID

Identification for each of TV

 

If we want to set all TV settings, TV ID can use “99” to achieve, and it will not

 

have Reply command on this function.

Command Type

Identify command type,

 

“s” (0x73h) : Set Command

Command:

Function command code: One byte ASCII code

Value[1~3]:

Three bytes ASCII that defines the value

CR

0x0D

Set-Function format

Send: (Command Type=”s”)

Name

Byte

Count

Bytes order

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

1 Byte

2 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

1 Byte

 

 

 

 

 

 

 

 

1

2~3

4

5

6

7

8

9

 

 

 

 

 

 

 

 

Reply: (Command Type=”+” or “-”)

Name

Byte

Count

Bytes order

Length

ID

Command Type

CR

1 Byte

2 Byte

1 Byte

1 Byte

 

 

 

 

1

2~3

4

5

 

 

 

 

Example1: Set Brightness as 76 for TV-02 and this command is valid Send (Hex Format)

 

Name

 

Length

ID

Command Type

Command

Value1

Value2

Value3

CR

 

Hex

 

0x38

0x30

0x73

0x24

0x30

0x37

0x36

0x0D

 

 

 

 

0x32

 

 

 

 

 

 

 

 

Reply (Hex Format)

 

 

 

 

 

 

 

 

 

Name

 

Length

ID

Command Type

CR

 

 

 

 

 

 

Hex

 

0x34

0x30

0x2B

0x0D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0x32

 

 

 

 

 

 

 

Example2: Set Brightness as 176 for TV-02 and this command is NOT valid Send (Hex Format)

Name

Length

ID

Command Type Command

Value1

Value2

Value3

CR

ViewSonic CD4620

46

Downloaded From TV-Manual.com Manuals

Page 49
Image 49
ViewSonic VS11915, CD4620 Value1~3, Set-Function description Length, Set-Function format Send Command Type=s