1.Push the TEST button on the GFCI. The RESET button will trip out, the GFCI indicator window will turn white and the top side digital control LED display will go out. If this does not happen, DO NOT USE THE VOYAGER. CALL DM INDUSTRIES LTD'S SERVICE CENTER FOR ASSISTANCE.

2.If the GFCI tests properly, firmly push the RESET button back into place. The GFCI indicator window will turn red and the top side digital control LED display will come back on. If this does not happen, DO NOT USE THE VOYAGER. CALL DM INDUSTRIES LTD'S SERVICE CENTER FOR ASSISTANCE.

3.If the GFCI trips by itself at any time, firmly press the RESET button back into place and perform the above tests. If this happens more than once, DO NOT USE THE VOYAGER. CALL DM INDUSTRIES LTD'S SERVICE CENTER FOR ASSISTANCE.

Once the Voyager is properly powered, the digital control will start the pump after a few seconds and water should start flowing through the jets. If no water is coming through, unplug the GFCI and repeat the priming procedure or see the trouble shooting chart on page 18.

Your Voyager spa has been designed to be simple to operate and maintain. It is equipped with state-of- the art digital control with LED readout (see previous page) to show temperature and time. The digital control has been factory programmed for your convenience. Once properly connected, the filtration pump and heater will automatically come on and heat the spa to 102

A. Displaying Time or Water Temperature. Pressing the "PROG" button will switch the display between time and water temperature.

B. Setting Temperature and Time

1.Press and hold down the "PROG" button for 5 seconds until the display starts flashing. Note that the display will be flashing during this procedure.

2.Press the "UP" or "DOWN" arrow to select the desired temperature.

3.Press the "PROG" button to show the "Hours".

4.Press the "UP" or "DOWN" arrow to select the current hour. Note the AM and PM indicators.

5.Press the "PROG" button to show the Minutes.

6.Press the "UP" or "DOWN" arrow to select the current minute.

7. Press "PROG" button to exit the programming mode or wait 30 seconds for normal display to appear

C. Auto Heat Operation.

Your spa is equipped with a 2-speed pump. The low speed operates during filtration and heating cycles. Your selected water temperature will be maintained automatically 24 hours a day. The electronic thermostat will monitor your water temperature at the top of each hour by cycling the low speed pump for 2 minutes. If the spa water temperature is below the set temperature, the heater will be activated until the water temperature reaches the set temperature, at which point both low speed pump and heater will turn off. If the water temperature is at the set temperature, the low speed pump will turn off at the end of the 2 minutes..

The spa water will heat at about 2 deg F per hour. Your selected water temperature will be maintained 24 hours a day. The maximum temperature is set at 104° F. Note that the heater will turn off when you are using the spa on therapy mode (Hi-speed of the pump). The heater only operates on low speed.

In case of an electrical power failure or if you disconnect your spa, the selected temperature and current time will be stored in memory. Once the power is restored, your spa will continue to operate as per your original choice. The time setting will obviously have to be corrected.

D. Jet Operation

The Voyager is equipped with a 2-speed or 2-mode therapy pump. The soft-mode (low speed) provides soft Relaxation Therapy and the power mode (hi-speed) provides vigorous Power Therapy.

JET Button: 1.Press "JET" to activate the Relaxation Therapy mode. (Low speed pump).

2.Press "JET" a second time to activate the Power Therapy mode. (High speed pump).

3.Press "JET" a third time to turn the pump off.

Note that the heater will turn off during therapy mode (hi-speed) to allow the spa to continue to operate on 15A 110V outlet. For safety, all jet modes will automatically turn off after 30 minutes. If needed, reactivate any therapy mode as indicated above. Remember that the low-speed mode is also controlled by the thermostat and the filtration cycle timer. The low-speed pump will remain on if the thermostat calls for heat or if you are operating the spa during the auto filtration cycle (8am to 11am & 4pm to 7pm).

ALWAYS CHECK THE WATER TEMPERATURE PRIOR TO ENTERING INTO YOUR SPA.

PAGE 11