SET UP AND INSTALLATION
Your Voyager spa is completely
Structure: The Voyager spa should always be placed on a structurally strong, relatively smooth and level surface. Concrete, bricks, stepping stone or treated wood deck are acceptable permanent surfaces. See specifications on page 22 for loading capacity.
Drainage: Do not place the Therapy module in an area where water will "puddle" around it. A self draining surface sloped 1 inch per 10 feet would be ideal.
Indoor installationPlease give special consideration to the following issues when installing your Voyager spa indoor.
1.Install your spa on water resistant,
2.Take into consideration the room humidity which will exist due to high temperatures. Providing natural or forced ventilation in the room will help maintain comfort and minimize moisture damage to the surrounding environ- ment and remove chemical odor in the air.
3.Indoor second story above finished living space should be avoided due to the possibility of water and humidity damage.
4.Allow full access to the spa equipment for service.Outdoor InstallationPlease take into account the following when considering outdoor installation.1.Local Building Codes.2.Provide a smooth surface (tile, concrete, wood, brick or sand) and verify that there are no sharp objects under the spa prior to set up.
3.Place your spa away from areas where debris and dirt may be tracked into the spa.
4.Consider privacy, sun exposure, and wind shielding. A sheltered environment can result in lower operating and maintenance costs.
5.It is recommended that the spa be placed in a location where it can be easily supervised when in use by children.
Allow easy access to the Ground Fault Circuit Interrupter (GFCI) which is located on the end of the power cord. The 110 Volt GFCI and the outlet it is plugged into should be protected from extreme weather, landscape sprinklers and accidental spills.
A pressure clamp wire connector is provided in the underside of the pump motor to permit connection of a minimum No.8 AWG (8.4mm) solid copper bonding conductor between this point and any metal equipment, metal enclosures or electrical equipment, metal water pipe or conduit, within 5 feet (1.5m) of the unit as needed to comply with local requirements.
Your Voyager spa has been carefully engineered to provide maximum safety against electrical shock. Installation must be within 15 feet of a three wire grounded 110V 15A outlet. The outlet should be a minimum of 5 feet from the spa. Connecting the Voyager spa to an improperly wired circuit, or using an extension cord may cause damage to the equipment that is not covered under warranty.
PACKING LISTBOX TYPE QUANTITY | CONTENT |
|
|
KEEP THE THERAPY MODULE’S ORIGINAL BOX. IT WILL BE NEEDED TO SHIP THE MODULE TO A WARRANTY STATION OR THE FACTORY IN THE UNLIKELY EVENT THE MODULE NEEDS SERVICING.
PAGE 4