FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
1)Reverse procedure to install and adjust blower position as outlined under "BLOWER ADJUSTMENT" in
"SERVICE PROCEDURES AND ADJUSTMENTS".
B.Motor - perform step 3A and continue procedure.
4.Remove the nuts that secure the motor mounting plate to the rear wall.
10.Reconnect lead wires at the motor, replace conduit and junction box cover.
NOTE: Check data plate on motor for wiring schematic. The motor must rotate clockwise when viewed from the shaft end.
5.Place a piece of cardboard on the bottom of the oven cavity to protect its surface from any damage during motor assembly removal.
6.Pull the motor assembly into the oven cavity and place it on the cardboard.
7.Remove the junction box cover from the motor, disconnect lead wires and remove the conduit.
8.Remove motor mounting bolts and flat washers then lift the motor from the mounting plate.
9.Position the replacement motor on the motor mounting plate and install mounting bolts and washers. Hand tighten mounting bolts only.
11.Slide blower onto motor shaft until hub is flush with end of shaft then tighten set screws.
12.Adjust motor position until blower is parallel to motor mounting plate as outlined under "BLOWER ADJUSTMENT" in "SERVICE PROCEDURES AND ADJUSTMENTS".
13.Position motor mounting plate on the rear wall and secure with nuts and washers.
14.Replace the baffle panel.
15.Remove cardboard from the bottom of the oven cavity.
16.Check oven for proper operation then replace rack guides and racks.
DOOR SWITCH
WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
1.Remove the top front cover as outlined under
"COVERS AND PANELS".
2.Disconnect the lead wires to the door switch.
3.Remove the switch.
Page 11 of 60 |
| F25105 (December 2001) |
|