FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

Listed below are the parameters and data you should find in the calibration Mode.

 

ALTERNATING ON

MENU

DISPLAY

 

PARAMETER

DATA

 

 

 

Calibrate

CALY

no

(must display no)

 

 

 

 

 

Logic Output Test

LgOt*

0

(see step 3)

*g displays as a 9

 

 

 

 

Logic Inputs "LI"

LI

21

(Factory Only)

 

 

 

 

 

Keyboard

HEY

0

(see step 4)

 

 

 

 

 

Display Test

 

sequence

 

of

(All segments of

---

characters

display and the

 

in display

LED’s are tested )

 

 

window

 

 

 

 

 

Exit Calibration

Set point temperature is

Mode and return

displayed or if call for heat,

to Operation

dashes (----) displayed.

Mode

 

 

 

 

 

NOTE: While in the calibration mode, on all parameters except the Logic Output Test (LgOt), the control outputs will be OFF.

To change the programmed data, use the arrow keys.

To select the next parameter, press the Rack 1 key.

At the end of the test, the control automatically exits the Calibration Mode and returns to the Operation Mode.

After 1 minute of no key activations, the control will return to operation mode.

1.Use this key sequence to access the calibration mode.

Up arrow; Down arrow; Rack 1; Down arrow; Temperature; Rack 1

2.Once in the calibration mode the display will alternate between the parameter and programmed data. The computer control outputs are turned OFF.

A.Convection fan stops.

B.Heating stops.

NOTE: If the control was calling for heat when the calibration mode was entered, heating will resume after exiting the test mode.

3.Press the Rack 1 key to accept the default "no" under the "CALY" (calibrate) parameter and advance the display menu to the "LgOt" (logic output) test. In this mode, the control and logic outputs can be turned ON for testing only.

A.Use the arrow keys to change the display to the appropriate number for testing. Each test starts automatically, several seconds after number is selected.

1)#0 - All control outputs are OFF (fan & heat OFF).

#1 - Heat comes ON (2CON is energized).

#5 - Convection fan comes ON (High or Low speed SSR is energized).

#8 - Electronic beeper (external) sounds.

B.If the output tests are completed successfully, proceed to step 4.

C.If the output tests are not completed successfully, find the source of the problem. If the problem cannot be repaired, replace the component and check for proper operation.

4.Press the Rack 1 key twice to advance past the "LI" (Logic Inputs test) and reach the "HEY (keyboard) test.

A.Press the desired key to display the corresponding hexadecimal code. This code is used internally by the control to identify the key being pressed. See table below.

KEY

CODE

KEY

CODE

 

 

 

 

Up Arrow

40

Start/Stop

4

 

 

 

 

Down Arrow

80

Temp

20

 

 

 

 

1/2 menu

800

Rack 1

10*

 

 

 

 

3/4 menu

4000

Rack 2

400

 

 

 

 

5/6 menu

2

Rack 3

2000

 

 

 

 

Set

200

Rack 4

1

 

 

 

 

Time

1000

Rack 5

8

 

 

 

 

Cook & Hold

8000

 

 

 

 

 

 

*displays 10 momentarily then alternates between Hey and 0. If pressed again, advances to the next test.

Page 27 of 60

 

F25105 (December 2001)

 