Vulcan-Hart VC4ES, VCIEC, VC6ED, VC6EC Computer Control Models Only, Symptoms, Possible Causes

Models: VC6ES VC4ED VC4ES VC6EC VC6ED VCIEC

1 60
Download 60 pages 50.54 Kb
Page 57
Image 57
COMPUTER CONTROL MODELS ONLY

FULL SIZE ELECTRIC CONVECTION OVENS - TROUBLESHOOTING

SYMPTOMS

 

POSSIBLE CAUSES

 

 

 

No power to oven controls.

1.

Main circuit breaker OPEN.

 

2.

Control circuit fuses OPEN.

 

3.

Power switch (S1) inoperative.

 

4.

Transformer (T2) inoperative (480V only).

 

 

 

No heat, convection fan motor runs.

1.

High limit thermostat OPEN.

 

2.

Heating element malfunction.

 

3.

Contactor malfunction.

 

4.

Temperature control malfunction.

 

 

 

No power to temperature control.

1.

Power switch (S1) in “Cool Down”.

 

2.

Door or door switch open.

 

 

 

Door does not seal or shut properly

1.

Doors out of adjustment.

 

2.

Door chain out of adjustment or broken

 

 

(simultaneous doors).

 

3.

Door catch roller out of adjustment or broken

 

 

(independent doors).

 

4.

Door seals damaged.

 

 

 

COMPUTER CONTROL MODELS ONLY

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

Oven does not heat.

1.

High limit switch open.

 

2.

Temperature probe malfunction.

 

3.

Computer control malfunction.

 

 

 

High limit thermostat shutting OFF heat.

1.

Temperature probe malfunction.

 

2.

Computer control malfunction.

 

 

 

Oven not hot enough.

1.

Temperature probe malfunction.

 

2.

Computer control range high (rH1) setting to low. See

 

 

"SETUP MODE" under "COMPUTER CONTROL)".

 

3.

Computer control malfunction.

 

 

 

Blower motor doesn’t run with power

1.

Line voltage incorrect.

switch in “ON” or "COOL DOWN” position.

2.

Power switch (S1) malfunction.

 

3.

Fan speed switch (S3) malfunction.

 

4.

Solid sate relay (SSR) malfunction. See "SOLID STATE

 

 

RELAY TEST" under "COMPUTER CONTROL".

 

5.

Interconnecting wiring malfunction.

 

6.

Motor inoperative.

 

7.

Computer control malfunction. See "COMPUTER

 

 

CONTROL OPERATIONAL TEST".

 

 

 

Page 57 of 60

 

F25105 (December 2001)

 

Page 57
Image 57
Vulcan-Hart VC4ES, VCIEC, VC6ED, VC6EC, VC4ED, VC6ES service manual Computer Control Models Only, Symptoms, Possible Causes