Vulcan-Hart VC6EC, VCIEC, VC6ED Component Panel Components, Temperature Probe Solid State Control

Models: VC6ES VC4ED VC4ES VC6EC VC6ED VCIEC

1 60
Download 60 pages 50.54 Kb
Page 8
Image 8
COMPONENT PANEL

FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS

COMPONENT PANEL

COMPONENTS

WARNING: DISCONNECT THE ELECTRICAL

POWER TO THE MACHINE AT THE MAIN

CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT

BOX INDICATING THE CIRCUIT IS BEING

SERVICED.

Removable Components

1.Remove the right side panel as outlined under

"COVERS AND PANELS".

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under "COVERS AND PANELS".

2.Disconnect the wire leads to the component being replaced.

3.Remove the component.

4.Reverse the procedure to install the replacement component and check oven for proper operation.

TEMPERATURE PROBE (SOLID STATE CONTROL)

WARNING: DISCONNECT THE ELECTRICAL

POWER TO THE MACHINE AT THE MAIN

CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT

BOX INDICATING THE CIRCUIT IS BEING

SERVICED.

1. Remove the right side panel as outlined under

"COVERS AND PANELS".

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under "COVERS AND PANELS".

2. Disconnect the probe leads from the solid state temperature control.

3. Remove the racks and right rack support.

4. Remove the probe guard or mounting clips.

F25105 (December 2001)

 

Page 8 of 60

 

Page 8
Image 8
Vulcan-Hart VC6EC, VCIEC, VC6ED Component Panel Components, Temperature Probe Solid State Control, Removable Components