OPERATION

OPERATION

BOILER CONTROLS — GAS (Figs. 2, 3) or ELECTRIC (Figs. 2, 4)

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

 

 

 

 

 

 

 

LOW

 

 

PRESSURE

 

 

 

 

 

 

 

WATER

 

 

 

 

 

 

 

LIGHT

 

 

 

 

 

LIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET SWITCH

 

 

 

 

 

 

 

 

(GREEN)

 

 

 

 

 

 

 

 

 

 

 

WATER

LEVEL

GAUGE

BOILER

PRESSURE

GAUGE

PL-41513-1

Fig. 2

Water Level Gauge

Power Switch

Press [ I ] to power the controls and begin filling the boiler.

Press [ O ] to turn the controls and the steamer off. The boiler automatically blows down for about 5 minutes.

High Pressure Light

Is lit after [ I ] is pressed and stays on during fill. Goes off after the reset switch is pressed (when green light is lit).

Is lit if pressure exceeds 15 psig.

Low Water Light

Is lit after [ I ] is pressed and stays on during fill. Goes off after the reset switch is pressed (when green light is lit).

Is lit if water level is too low.

Reset Switch

When the high pressure and low water limits are satisfied, the green light in the reset button will come on. Press the reset button to clear high pressure and low water limit lights and start or resume normal operation.

Boiler Pressure Gauge

Indicates the boiler steam pressure; the normal operating range is 5 to 12 psig.

The correct water level is approximately 1" (2.5 cm) of water in the water level gauge sight glass.

The manual valves at the top and bottom of the water level gauge (Fig. 3) must be fully open (counterclockwise).

Observe that the water is clean and clear in the glass tube.

The appearance of extreme murkiness in the water indicates inadequate water quality and will cause the controls and the steamer to fail. Warranty does not cover malfunction due to poor water conditions.

Pressure Relief Valve

The pressure relief valve, located on the top left side, prevents pressure in the boiler from exceeding 15 psig.

Manually pull up the lever daily to reduce scale buildup and verify that the pressure relief valve functions properly.