Vulcan-Hart VL2GAS, VL3GMS, VL2GMS, VL3GAS, VL2GSS, VL3GSS, VL3GPS, VL2GPS service manual Number

Models: VL2GPS VL3GPS VL3GSS VL2GSS VL2GAS VL3GAS VL2GMS VL3GMS

1 88
Download 88 pages 1.61 Kb
Page 35
Image 35
NUMBER

VL SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS

 

 

 

 

 

 

 

 

 

 

 

NUMBER

KW

AMPERAGE

RESISTANCE

 

 

TOTAL

PER LINE

PER

 

 

OF

PER

 

VOLTAGE

KW

 

 

ELEMENT

 

ELEMENTS

ELEMENT

1 PH

3 PH

 

 

 

(OHMS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208

18

2

9

87

50

14.42

 

 

 

 

 

 

 

 

 

240

18

2

9

75

44

19.20

 

 

 

 

 

 

 

 

 

480

18

2

9

 

22

76.80

 

*220/380

18

2

9

 

25

19.20

 

240/415

 

 

 

 

 

 

 

 

 

208

24

2

12

116

68

10.82

 

 

 

 

 

 

 

 

 

240

24

2

12

100

58

14.40

 

 

 

 

 

 

 

 

 

480

24

2

12

 

29

57.60

 

*220/380

24

2

12

 

34

14.40

 

240/415

 

 

 

 

 

 

 

 

 

208

36

4

9

 

100

14.42

 

240

36

4

9

 

87

19.20

 

480

36

4

9

 

44

76.80

 

*220/380

36

4

9

 

50

19.20

 

240/415

 

 

 

 

 

 

 

 

 

208

42

4

10.5

 

117

12.36

 

240

48

4

12

 

116

14.40

 

480

48

4

12

 

58

57.60

 

*220/380

48

4

12

 

67

14.40

 

240/415

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Values in the table are nominal. Tolerance is +/-10 %.

2.Asterisk (*) indicates 3 phase/4wire.

3.Each heater has three internal elements.

Page 35 of 88