Vulcan-Hart VL3GMS, VL2GMS, VL3GAS, VL2GAS, VL2GSS, VL3GSS, VL3GPS Vl Series Steamer - Troubleshooting

Models: VL2GPS VL3GPS VL3GSS VL2GSS VL2GAS VL3GAS VL2GMS VL3GMS

1 88
Download 88 pages 1.61 Kb
Page 88
Image 88
Manual background

VL SERIES STEAMER - TROUBLESHOOTING

 

 

 

 

 

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

 

 

Pilot not lit or goes out.

1.

Gas not on.

 

 

2.

Pilot going out due to drafts, excess steam from drain or

 

 

 

steamer not level. Improper venting can direct the pilot

 

 

 

flame away from thermopile or flame sensor.

 

 

3.

Low incoming gas pressure. See “GAS MANIFOLD

 

 

 

PRESSURE ADJUSTMENT” in “SERVICE

 

 

 

PROCEDURES”.

 

 

4.

Pilot not adjusted correctly. See “PILOT AND

 

 

 

THERMOCOUPLE ASSEMBLY (GAS MODELS)” in

 

 

 

“SERVICE PROCEDURES AND ADJUSTMENTS”.

 

 

5.

Check thermopile millivolts. See “PILOT AND

 

 

 

THERMOCOUPLE ASSEMBLY (GAS MODELS)” in

 

 

 

“SERVICE PROCEDURES AND ADJUSTMENTS”.

 

 

6.

Burners ignite too violently. Check gas pressure to the

 

 

 

steamer. See “GAS MANIFOLD PRESSURE

 

 

 

ADJUSTMENT” in “SERVICE PROCEDURES”.

 

 

7.

If auto ignition and no sparking - ignition module

 

 

 

malfunction.

 

 

8.

Wrong pilot assembly used.

 

 

 

 

 

Spark Ignitor not sparking.

1.

Poor ground between pilot bracket and burner.

 

 

2.

Loose, broken or damaged lead wires (including ground)

 

 

 

from ignition module to ignitor.

 

 

3.

Ignitor boot on ignition cable loose, damaged or missing

 

 

 

causing excessive ignition voltage leakage.

 

 

4.

Ceramic flame rod insulator on ignitor cracked or damaged

 

 

 

from extreme heat.

 

 

5.

Incorrect spark gap setting. See “AUTOMATIC IGNITION

 

 

 

SYSTEMS (GAS MODELS)” in “SERVICE

 

 

 

PROCEDURES”.

 

 

6.

Ignition module not receiving power. Check to ensure the

 

 

 

ignition control module reset switch is ON.

 

 

7.

Ignition module malfunction.

 

 

 

 

Form 24650 (May 1999)