Vulcan-Hart VL2GPS, VL3GMS, VL2GMS, VL3GAS, VL2GAS, VL2GSS Gas Models Only, Symptom, Possible Causes

Models: VL2GPS VL3GPS VL3GSS VL2GSS VL2GAS VL3GAS VL2GMS VL3GMS

1 88
Download 88 pages 1.61 Kb
Page 87
Image 87
GAS MODELS ONLY

VL SERIES STEAMER - TROUBLESHOOTING

GAS MODELS ONLY

 

 

 

 

 

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

 

 

Burner won’t light.

1.

Gas not on.

 

 

2.

Ignition control module reset switch in the OFF position or

 

 

 

malfunctioning.

 

 

3.

Ignition module not receiving power. Check ignition module

 

 

 

transformer for 24VAC output to module on automatic

 

 

 

ignition systems.

 

 

4.

Steamer not properly grounded and/or polarity of incoming

 

 

 

power is incorrect on automatic ignition systems.

 

 

5.

Low incoming gas pressure. See “GAS MANIFOLD

 

 

 

PRESSURE ADJUSTMENT” in “SERVICE

 

 

 

PROCEDURES”.

 

 

6.

Ignition module malfunction.

 

 

7.

Gas combination control valve malfunction.

 

 

8.

Boiler not filling. Check fill solenoid for power, clogging or

 

 

 

malfunction.

 

 

9.

Water level control malfunction. HL-3 relay not energizing

 

 

 

or contacts not closing to power boiler fill solenoid.

 

 

10.

Water too ”pure” for probes to properly conduct electricity.

 

 

11.

High limit thermostat open (if equipped).

 

 

12.

High limit pressure switch open.

 

 

13.

Cycling pressure switch open or set too high. Steamer is

 

 

 

cycling on high limit. See “CYCLING AND HI LIMIT

 

 

 

PRESSURE SWITCHES (GAS AND ELECTRIC MODELS)

 

 

 

in SERVICE PROCEDURES”.

 

 

 

 

 

Burner won’t stay lit.

1.

Gas pressure low. See “GAS MANIFOLD PRESSURE

 

 

 

ADJUSTMENT” in “SERVICE PROCEDURES”.

 

 

2.

Check gas orifice for obstruction.

 

 

3.

Ignition module malfunction.

 

 

 

 

Page 87 of 88