TROUBLESHOOTING

VL SERIES STEAMER - TROUBLESHOOTING

TROUBLESHOOTING

ALL MODELS

WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.

 

 

 

 

 

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

 

 

Compartment leaks water around door.

1.

Drain screen clogged.

 

 

2.

Drain line obstructed or not to an open gap drain.

 

 

3.

Steamer not level.

 

 

4.

Excessive cooking compartment pressures.

 

 

 

A. On models equipped with the compartment pressure

 

 

 

regulating valve, verify the compartment pressure is 6

 

 

 

psi during cooking. If pressure is higher then adjust the

 

 

 

pressure regulating valve and re-check. See

 

 

 

COMPARTMENT PRESSURE ADJUSTMENT” in

 

 

 

“SERVICE PROCEDURES AND ADJUSTMENTS”.

 

 

 

B. On models with out the compartment pressure

 

 

 

regulating valve, verify the compartment pressure is 6

 

 

 

psi during cooking. If pressure is higher then adjust the

 

 

 

cycling pressure switch and re-check. See “CYCLING

 

 

 

AND HIGH LIMIT PRESSURE SWITCHES (GAS AND

 

 

 

ELECTRIC MODELS)” in “SERVICE PROCEDURES

 

 

 

AND ADJUSTMENTS”.

 

 

 

 

 

Cold water condenser not operating

1.

Water supply not on.

 

properly.

2.

Plugged spray nozzle.

 

 

 

 

3.

Cold water condenser solenoid inoperative or plugged.

 

 

4.

Cold water condenser thermostat malfunction or needs

 

 

 

adjustment.

 

 

5.

No power to cold water condenser solenoid.

 

 

 

 

 

Steam leaks around door.

1.

Compartment door not properly sealed.

 

 

2.

Worn or damaged gasket.

 

 

3.

Drain line obstructed or not to an open drain.

 

 

 

 

 

Steam generated inside compartment

1.

Steam gate valve not fully closing (clogged, dirty or

 

when timer or compartment power switch

 

malfunctioning). See “STEAM GATE VALVE” in “SERVICE

 

is OFF.

 

PROCEDURES”.

 

 

 

 

 

Heat coming on without water in boiler

1.

Lime scale (moist) on LLCO water level probe or probe

 

(Dry firing).

 

damaged (shorted to ground).

 

 

2.

Retention of water in probe canister assembly.

 

 

3.

Water level control malfunction.

 

 

 

 

 

Pressure relief valve opening or leaking.

1.

Pressure relief valve malfunction.

 

 

2.

Cycling pressure switch set to high. See “CYCLING AND HI

 

 

 

LIMIT PRESSURE SWITCHES (GAS AND ELECTRIC

 

 

 

MODELS)” in “SERVICE PROCEDURES”.

 

 

 

 