VL SERIES STEAMER - TROUBLESHOOTING

 

 

 

 

 

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

 

 

Cooking timer motor does not run.

1.

Timer not getting power.

 

 

2.

Timer motor inoperative.

 

 

 

 

 

Buzzer not operating.

1.

Cooking timer malfunction.

 

 

2.

Buzzer malfunction.

 

 

 

 

 

Compartment red light and timer do not

1.

Thermal switch (load compensator) is set too high.

 

come on; excessive time elapses before

 

 

 

they come on; timer stops, the red light

 

 

 

goes out, and the buzzer does not sound

 

 

 

after compartment exhausts steam; time

 

 

 

is set as usual for the product and the

 

 

 

product is overcooked.

 

 

 

 

 

 

 

Short a time between starting and the red

1.

Thermal switch (load compensator) is set too low.

 

light coming on; red light comes on

 

 

 

immediately; time is set as usual for the

 

 

 

product and the product is undercooked.

 

 

 

 

 

 

 

Cooking Compartment Controls

1.

Ensure that voltage is reaching control circuit through

 

inoperative

 

compartment power switch when turned ON.

 

 

2.

On electric heat models with a transformer, check step down

 

 

 

transformer (located in the contactor box) for proper

 

 

 

operation.

 

 

3.

Check cooking timer function and contact position. See

 

 

 

“SCHEMATIC AND WIRING DIAGRAMS -

 

 

 

COMPARTMENT CONTROLS” under “ELECTRICAL

 

 

 

OPERATION”.

 

 

4.

Check that timer motor operates when connected to power. If

 

 

 

a problem is found in timer, replace it, do not take timer

 

 

 

apart.

 

 

5.

On prevent and automatic models check the load

 

 

 

compensator for malfunction.

 

 

6.

Check wiring for damaged insulation. (no short circuit)

 

 

7.

Check that all connections and terminals are securely

 

 

 

fastened. (no open circuits)

 

 

8.

Check that all connections are made according to

 

 

 

compartment control wiring diagram.

 

 

 

 

 

Cooking Compartment not venting at end

1.

Steam control arm not returning after unlatching (automatic,

 

of cook cycle (Prevent models) or when

 

standard and manual models).

 

manual steam control arm is released.

 

A. Broken or missing return spring.

 

 

 

 

 

 

B. Packing nut on steam gate valve to tight.

 

 

 

C. Steam control (trip) solenoid malfunction (prevent and

 

 

 

automatic models).

 

 

2.

Steam exhaust solenoid valve malfunctioning (prevent

 

 

 

models).

 

 

 

 

Page 86 of 88