Allowed Connections

VT1433B User's Guide

Break Out Boxes

Recommendations on wiring for the VT1432A/33B 4-Channel Input Connector

Allowed Connections

Differential Input Channels

Connect at VT1432A/33B end of cabling and at DUT

Recommended: shielded twisted pair

1+ Diff 4

2- Diff 4

5+ Diff 3

6- Diff 3

8+ Diff 2

9- Diff 2

12+ Diff 1

13- Diff 1

Input Channel Shielding

Connect at VT1432A/33B end of cabling ONLY

3RFI GND/Drain Shield 4

4RFI GND/Drain Shield 3

10RFI GND/Drain shield 2

11RFI GND/Drain Shield 1

Additional shielding of entire cable

GND for grounded measurements if required

14

RFI GND/Cable Shield

26

RFI GND/Cable Shield