VT1433B User's Guide

The Host Interface Library

Parameter Information

Description of VT1433B Parameters

Some parameters, such as range or coupling, apply to specific channels. When a channel ID is given to a function that sets a channel-specific parameter, only that channel is set to the new value.

Some parameters, such as clock frequency or data transfer mode, apply globally to a module. When a channel ID is used to change a parameter that applies to a whole module, the channel ID is used to determine which module. The parameter is then changed for that module.

Starting and stopping a measurement is somewhat like setting a global parameter. Starting a measurement starts each active channel in each module that has a channel in the group.

After firmware is installed and after a call to e1432_preset, all of the parameters (both channel-specific and global) in a VT1433B module are set to their default values. For channel-specific parameters, the default value may depend on the type of channel. Some channel-specific parameters apply only to a specific type of channel. For example, tach holdoff applies only to tach channels. Setting such a parameter for a channel that doesn’t make sense will result in an error.

At the start of a measurement, the VT1433B firmware sets up all hardware parameters and ensures that the input hardware is settled before starting to take data. The firmware also ensures that any digital filters have time to settle. This ensures that all data read from the module will be valid.

However, after a measurement starts, VT1433B parameters can still be changed. The effect of this change varies, depending on the parameter. For some parameters, changing the value aborts the measurement immediately. For other parameters, the measurement is not aborted, but the changed parameter value is saved and not used until a new measurement is started. For still other parameters, the parameter change takes place immediately and the data coming from the module may contain glitches or other effects from changing the parameter.

The module cannot be told to wait for settling when changing a parameter in the middle of a measurement. The only way to wait for settling is to stop and re-start the measurement. The settling that takes place at the start of a measurement cannot be disabled as well.

4-4

Page 82
Image 82
VXI manual Parameter Information, Description of VT1433B Parameters

VT1433B specifications

The VXI VT1433B is a versatile and sophisticated instrument designed for testing and measurement applications, particularly in the realm of telecommunications and electronics. Designed with the needs of engineers in mind, it brings a comprehensive set of features and technologies that enable accurate and efficient performance.

One of the standout features of the VT1433B is its ability to function as a high-performance data acquisition system. With up to 32 input channels, users can capture a wide range of signals simultaneously. This capability is particularly beneficial for applications requiring the monitoring of multiple parameters or systems concurrently, such as in complex electronic testing scenarios.

The VT1433B utilizes advanced technology for signal processing and analysis. Equipped with high-resolution analog-to-digital converters, the unit ensures precise measurement of various signal types, including voltage, current, and frequency. This precision is critical for engineers who rely on accurate data to make informed decisions during the design and testing phases.

In addition to its measurement capabilities, the VT1433B also supports multiple communication protocols, including GPIB, USB, and LAN, allowing for easy integration into existing test systems. This flexibility enhances its usability in both laboratory settings and field operations, where different setups may be required.

The instrument also comes with a user-friendly interface, featuring a clear display and intuitive controls that simplify operation. This design consideration allows users, regardless of their experience level, to navigate the system seamlessly and access the features they need without unnecessary delays.

Moreover, the VT1433B incorporates robust software support, including various programming tools and libraries. This aspect allows for easy implementation of automated test sequences and extensive data analysis capabilities, streamlining the workflow significantly.

Another notable characteristic of the VT1433B is its reliability and durability, designed to withstand the rigors of continuous use in demanding environments. It is engineered to operate under a broad range of temperatures and conditions, making it suitable for diverse applications, from laboratory research to field testing.

In summary, the VXI VT1433B stands out as a comprehensive testing solution, characterized by its extensive input channels, high precision measurement capabilities, multi-protocol communication, user-friendly interface, and robust software support. This combination of features and technologies makes it an invaluable tool for engineers and researchers looking to optimize their testing and data acquisition processes in various fields.