AI232 Version 9.6x User’s Guide

AI232 Commands: Commands Overview

Using winslc Commands

To use winslc commands, the user must be logged into AI198 to receive output from AI232. AI198 relays the command to AI232, which processes the command and sends the result to the system log port (as configured in AI198 Menu 1.1). Valid winslc commands are:

z

arp

z

pvclist

z

break

z

router

z

creset

z

show

z

diag-tconn

z

staeia

z

help

z

staslc

z

ip

z

tcpoutconn

z

link

z

telnet

z

panic

z

update

z

ping

z

xon-interval

From the AI198, you can view the available winslc commands by entering the following command:

winslc baseport help

where baseport specifies the baseport number of AI232.

Log/Alarm Message Header

To obtain output from winslc commands, enable the activity/alarm log (AI198 Menu 1.1, menu item 01*The activity and alarm log is turned). The first line of the response for most winslc commands shows the following standard log/alarm message header:

>@AI19807:42:26 081104 Sev=F Base=016 Msg:

Table 8-1 describes the Log/Alarm message header elements.

Table 8-1 Log/Alarm Message Header Elements

Header Element

Description

 

 

@AI198

Specifies the node name for the device that is producing the

 

log/alarm message (in this case, AI198).

 

 

7:42:26

Specifies the current time.

 

 

8-4

Page 176
Image 176
Kentrox AI232 manual Using winslc Commands, Log/Alarm Message Header, Header Element Description