Kentrox AI232 manual Server that had a sequence number that was out of order

Models: AI232

1 322
Download 322 pages 30.19 Kb
Page 278
Image 278

AI232 Version 9.6x User’s Guide

AI232 Commands: tacacs stats

Display Item

Description

 

 

Wrong Header

Displays the number of packets received from the TACACS+

Sequence Number

server that had a sequence number that was out of order.

 

 

 

Wrong Header

Displays the number of packets received from the TACACS+

Session ID

server that had an invalid session ID.

 

 

 

Wrong Body Length

Displays the number of packets received from the TACACS+

 

server that had a body length attribute that did not match the

 

actual length of body received.

 

 

Write Errors

Displays the number of errors that occurred when AI232

 

attempted to send a packet to the TACACS+ server.

 

 

Read Errors

Displays the number of errors that occurred when AI232

 

attempted to read a packet from the TACACS+ server.

 

 

Short Header

Displays the number of incomplete headers that were received

Received

when AI232 attempted to read a packet from the TACACS+

 

 

server.

 

 

Short Body

Displays the number of packets with incomplete bodies that

Received

were received when AI232 attempted to read them from the

 

 

TACACS+ server.

 

 

Timed-out waiting

Displays the number of times AI232 timed out while waiting for

for response

a response from the TACACS+ server. For information about

 

 

configuring the time out value, refer to command aaa timeout

 

on page 8-19.

 

 

8-106

Page 278
Image 278
Kentrox AI232 manual Server that had a sequence number that was out of order, Server that had an invalid session ID