AI232 Version 9.6x User’s Guide

AI232 Commands: staslc

Examples

This example displays the link and cable status information for links 1 to 5.

[232]staslc 1-5

 

 

 

 

 

 

 

 

 

 

 

Link

Status Appl. DTR RTS CTS DSR DCD

Format

 

Parity Frame Overun Underun

1:

Idle Login

+

+

-

-

-

9600,8,n,1

0

0

0

0

2: Disabled Login

?

?

?

?

?

9600,8,n,1

0

0

0

0

3:

-MMUX

?

?

?

?

?

19200

 

0

0

0

0

4: Disabled Login

?

?

?

?

?

9600,8,n,1

0

0

0

0

5: Disabled Login

?

?

?

?

?

9600,8,n,1

0

0

0

0

DP232 Cable Status: Ports 1-8

 

Connected

Ports 9-16

Not Connected

 

 

 

Ports 17-24 Not Connected

Ports 25-32 Not Connected

 

[232]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Note: Not all links are displayed here. Entering the command with no additional parameters would show all 32 links.

Column

Description

 

 

Link

Displays the number of the link.

 

 

Status

Displays the link status as dataxfer (data is being transfered),

 

idle, or disabled.

 

 

Appl.

Displays the application specified for the link (Alias, Login, or

 

Destination).

 

 

DTR RTS CTS DSR DCD

Displays the status of the control signals. (+ means the signal

 

is asserted and - means the signal is negated.)

 

 

Format

Displays the baud rate, number of data bits, parity (none, odd,

 

or even), and number of stop bits specified for the link.

 

 

Parity

Displays the number of parity errors.

 

 

Frame

Displays the number of framing errors.

 

 

Overun

Displays the number of overrun errors.

 

 

Underun

Displays the number of underrun errors.

 

 

8-93

Page 265
Image 265
Kentrox AI232 manual Displays the number of the link, Is asserted and means the signal is negated