AI232 Version 9.6x User’s Guide

Link Configuration: RTS/DTR Lead Control Configuration

RTS/DTR Lead Control Configuration

The following configuration items are available for RTS and DTR lead control configuration:

zDTR State Configuration

zRTS State Configuration

DTR State Configuration

Description

DTR is an RS-232 signal sent from a computer or terminal to a modem that indicates that it (the computer or terminal) is able to accept data. DTR lead control is configured using two menu items:

zDTR connect state—Sets the DTR connect state to ON or OFF. ON sets DTR to on while the link is connecting and while it is connected. OFF turns this functionality off.

zDTR disconnect state—Sets the DTR disconnect state to one of the following options:

z ON—Sets DTR to on when the link disconnects. z OFF—Sets DTR to off when the link disconnects.

z TOGGLE—Makes DTR pulse when the link disconnects. The pulse polarity is opposite to the sense specified for the connected state.



Note: The RTS/DTR lead control options only take effect when the link is configured as a destination link.

Menu Item Type

Toggle

Link Type Availability

Async and AsyncPPP

Configuration in the AI198 Menu System

1.For an asynchronous or asynchronous PPP link, access Menu 4.2.14.12.13.

2.For 01*DTR connect state, enter 1 to select ON or OFF. The default is ON.

3.For 02*DTR disconnect state, enter 2 to select ON, OFF, or TOGGLE. The default is OFF.

5-45

Page 125
Image 125
Kentrox AI232 manual RTS/DTR Lead Control Configuration, DTR State Configuration