AI232 Version 9.6x User’s Guide
Link Configuration: General Link Properties Configuration
5-18
This ModMux link example displays 08 Auto Disable Error Limit set to 25000.
Configuration in the AI232 Local Menu System
1. Access the Link Menu.
2. Select Auto Disable Menu. The Link Auto Disable Menu appears.
3. For Errors/second limit for auto disable, enter the error limit value. The default
is 0.
This example displays Errors/second limit for auto-disable set to 25000.
Flow Control
Description
This menu item enables a receiving device to tell a sending device to stop sending
data when data is coming too fast and to start sending data when the receiver is
ready.
There are two available flow control options for AI232:
zNone—Specifies no flow control.
zXonXoff—Specifies the flow control option that uses standard ASCII control
characters to tell a sending device to stop or resume data transmission.
Menu Item Type
Toggle
Link Type Availability
Async, AsyncPPP, and ModMux
>8,25000
Menu 4.2.14.12
01 Link Number (1-32)--------------------------------------------------------01
02*Link Type (Async, AsyncPPP, ModMux)--------------------------------- ModMux
03 Link Description------------------------------ Async link 1
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05+Port speed------------------------------------------------------------- 9600
06*Flow Control (None, XonXoff)----------------------------------------- None
07 Xon Repeat interval (0 - 120s with 0 = no repeat)------------------------000
08 Auto Disable Error Limit (0-1000000)---------------------------------0025000
Link Auto Disable Menu
Link being configured . . . . . . . . . . . . . . . . . . . . . . . . . 03
Errors/second limit for auto-disable . . . . . . . . . . . . . . . . . . 25000