AI232 Version 9.6x User’s Guide

Link Configuration: General Link Properties Configuration

Port Data Bits

Description

This menu item defines the number of databits in a data byte.

Menu Item Type

Toggle

Link Type Availability

Async and AsyncPPP

Configuration in the AI198 Menu System

1.

Access Menu 4.2.14.12.

 

2.

For 06*Port Data Bits, enter 6 to select 7 or 8. The default is 8.

 

This example displays 06*Port Data Bits set to 7.

 

 

 

 

 

>6

 

 

 

Menu 4.2.14.12

 

01 Link Number (1-32)--------------------------------------------------------

01

 

02*Link Type (Async, AsyncPPP, ModMux)---------------------------------

Async

 

03 Link Description------------------------------

Async link 1

 

04*Link state (Enabled, Disabled)--------------------------------------

Enabled

 

05+Port speed-------------------------------------------------------------

9600

 

06*Port Data Bits (7, 8)------------------------------------------------------

7

 

 

 

Configuration in the AI232 Local Menu System

1.Access the Async Link Menu or AsyncPPP Link Menu.

2.For Port data bits, select Seven or Eight. The default is Eight.

5-23

Page 103
Image 103
Kentrox AI232 manual Port Data Bits, Async and AsyncPPP