AI232 Version 9.6x User’s Guide
Link Configuration: General Link Properties Configuration
5-29
This example displays 10 Xon Repeat interval set to 30.
Configuration in the AI232 Local Menu System
1. Access the Async Link Menu or AsyncPPP Link Menu.2. For XON Repeat Interval, enter a interval value. The default is 0.This example displays XON Repeat Interval set to 30.
>10,30
Menu 4.2.14.12
01 Link Number (1-32)--------------------------------------------------------03
02*Link Type (Async, AsyncPPP, ModMux)--------------------------------- Async
03 Link Description------------------------------ New Async Link
04*Link state (Enabled, Disabled)-------------------------------------- Enabled
05+Port speed------------------------------------------------------------- 4800
06*Port Data Bits (7, 8)------------------------------------------------------8
07*Port Stop Bits (1, 2)------------------------------------------------------2
08*Port Parity (None, Odd, Even)------------------------------------------- Odd
09*Flow Control (None, XonXoff)----------------------------------------- None
10 Xon Repeat interval (0 - 120s with 0 = no repeat)------------------------030
Async Link Menu
Link to configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Link Description . . . . . . . . . . . . . . ................ New Async Link
Link state . . . . . . . . . . . . . . . . . . . . . [Enabled] Disabled
Link Type . . . . . . . . . . . . . . . . . [Async] AsyncPPP ModMux
Port speed (in bits per second):
300 1200 2400 4800 [9600] 19.2K 38.4K 57.6K 115.2K
Autobaud
Port data bits . . . . . . . . . . . . . . . . . . . . . Seven [Eight]
Port stop bits . . . . . . . . . . . . . . . . . . . . . . . [One] Two
Port parity . . . . . . . . . . . . . . . . . . . . [None] Even Odd
SW Flow Control . . . . . . . . . . . . . . . . . . . . [None] XonXoff
XON Repeat Interval (0 - 120s with 0 = no repeat) . . . . . . . . . . . . 30